There are two ways to set up this function.
- Meter click charge enabled (SP5-930-001 set to "1 (enabled)"; this is the default setting): The counter can be displayed and printed by the customer. The service representative can then call the customer and ask for the counter.
- Meter click charge disabled (SP5-930-001 set to "0 (disabled)"): The counter cannot be displayed or printed by the customer. To check the counter, the service representative must print the SMC report (SP 5-990).
Item | SP No. | Function | Default |
---|---|---|---|
Meter Click Charge | SP5-930-001 | Enables or disables Meter Click Charge. When enabled:
When disabled:
| 1: ON |
Meter Click Charge: Maintenance Kit | SP5-931-001 | Enables or disables the PM alert for the maintenance kit. * This setting is unnecessary with this machine since this machine does not have the maintenance kit. | 1: No alert |
Counter Method (IM 550F/IM 600F/IM 600SRF Only) | SP5-045-001 | Specifies the counter display method.