SP Number | Selection Def. | Overview |
---|---|---|
SP5-886-111 | 0: OFF 1: ON | Sets auto update ON/OFF by ARFU. |
SP5-886-112 | 0: OFF 1: ON | Will not run the update when update prohibited time setting is ON and the current time is in the range of the time set.
|
SP5-886-113 | 0 to 23 9 | |
SP5-886-114 | 0 to 23 17 | |
SP5-886-115 | 0: OFF 1: ON | Even when the auto update function is disabled, downloading the package is allowed. The downloaded package can be used with SFU. |
SP5-886-116 | Display only | Displays when the latest package check will run. |
SP5-886-117 | 1 to 24 1 | Set time for the next version check after retry. |
SP5-886-120 | 0x00 | The update will not run if the corresponding bit for each day below is set to 1.
This setting is not affected by the prohibited time setting. e.g.) Prohibited on Mon., Fri., Sat., and Sun. : 0x47 (01000111) |
SP7-520-011 to 015 | Display only | History of date and time when the update has started. The five most recent are recorded, the lowest number being the most recent. If the last update failed, this is not recorded. |
SP7-520-021 to 025 | Display only | History of date and time when the update has finished. The five most recent are recorded, the lowest number being the most recent. The record is created when the update has successfully finished. When the update is canceled, no record is created. |
SP7-520-031 to 035 | Display only | History of the package number (including suffix) for which update has completed. The five most recent are recorded, the lowest number being the most recent. The record is created when the update has successfully finished. When the update is canceled, no record is created. |
SP7-520-041 to 045 | Display only | History of the package version for which update has completed. The five most recent are recorded, the lowest number being the most recent. The record is created when the update has successfully finished. When the update is canceled, no record is created. |