SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC670-01

D

Engine does not startup during the starting up

  • /ENGRDY signal was not asserted when the machine was turned on.
  • PCI I/F is not linked up when the machine returns from energy saver mode.
  • EC/PC/SC response was not received within the specified time from power on.
  • Writing to Rapi driver failed (the other party not found through PCI).
  • Connection defect between controller board (PCB15) and BiCU (PCB16).
  • BiCU (PCB16) is down/unstable

Engine board does not startup.

Refer to SC670 (engine startup error) is displayed.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC670-02

D

Engine does not start up after the starting up

  • CPU reset by software
  • CPU reset by anomaly CPU
  • CPU reset by hardware defect/noise
  • Hardware defect

Engine board reset unexpectedly.

Refer to SC670 (engine startup error) is displayed.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC670-03

D

IPU start up error when the machine boots up

VDET_EPCI signal was not asserted when the machine was turned on.

  • IPU, PSU (PCB18), and/or controller board (PCB15) defective
  • Incorrect connection between controller board (PCB15) and IPU.
  • Harness of IPU disconnected

Refer to SC670 (engine startup error) is displayed.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC670-04

D

Communication error between the engine and controller

Communication could not linked up.

  • IPU and/or controller board (PCB15) defective
  • Incorrect connection between controller board (PCB15) and IPU.

Refer to SC670 (engine startup error) is displayed.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC670-05

C

Link up error

Communication could not linked up.

  • CTL board defective
  • BiCU (PCB16) defective
  • Incorrect connection between CTL and BiCU (PCB16).

Logging only.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC672-00

D

Controller startup error

After the machine was powered on, communication between the controller and the operation panel was not established.

  • Controller stalled
  • Board installed incorrectly
  • Controller board (PCB15) defective
  • Operation panel connector loose, broken, or defective
  • Controller late
  1. Turn the main power OFF/ON.
  2. Check the connection of the operation panel.
  3. Check the connection of the controller board (PCB15).
  4. Replace the controller board (PCB15).

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC672-10

D

Controller startup error

After the machine was powered on, communication between the controller and the operation panel was not established.

  • Controller stalled
  • Board installed incorrectly
  • Controller board (PCB15) defective
  • Operation panel connector loose, broken, or defective
  • Controller late
  1. Turn the main power OFF/ON.
  2. Check the connection of the operation panel.
  3. Check the connection of the controller board (PCB15).
  4. Replace the controller board (PCB15).

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC672-11

D

Controller startup error

After the machine was powered on, communication between the controller and the operation panel was not established, or communication with the controller was interrupted after a normal startup.

  • Controller stalled
  • Board installed incorrectly
  • Controller board (PCB15) defective
  • Operation panel connector loose, broken, or defective
  • Controller late
  1. Turn the main power OFF/ON.
  2. Check the connection of the operation panel.
  3. Check the connection of the controller board (PCB15).
  4. Replace the controller board (PCB15).

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC672-12

D

Controller startup error

Communication with the controller was interrupted after a normal startup.

  • Controller stalled
  • Board installed incorrectly
  • Controller board (PCB15) defective
  • Operation panel connector loose, broken, or defective
  • Controller late
  1. Turn the main power OFF/ON.
  2. Check the connection of the operation panel.
  3. Check the connection of the controller board (PCB15).
  4. Replace the controller board (PCB15).

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC672-13

D

Controller startup error

The operation panel detects that the controller is down due to other reason, shown in SC672-10, SC672-11, and SC672-12.

  • Controller stalled
  • Board installed incorrectly
  • Controller board (PCB15) defective
  • Operation panel connector loose, broken, or defective
  • Controller late
  1. Turn the main power OFF/ON.
  2. Check the connection of the operation panel.
  3. Check the connection of the controller board (PCB15).
  4. Replace the controller board (PCB15).

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC672-99

D

Controller startup error

The operation panel software ended abnormally.

  • Controller stalled
  • Board installed incorrectly
  • Controller board (PCB15) defective
  • Operation panel connector loose, broken, or defective
  • Controller late
  1. Turn the main power OFF/ON.
  2. Check the connection of the operation panel.
  3. Check the connection of the controller board (PCB15).
  4. Replace the controller board (PCB15).