SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC396-01

D

Drum Motor (M6) Error 1

The drum motor (M6) is not stabilized within 2 seconds after the motor is activated.

  • Connector disconnected or defective
  • Drive transmission of the Drum motor (M6) defective
  • Drum motor (M6) defective
  • IOB (PCB17) defective
  • Connector disconnected or defective
    Reconnect the following connector. Then perform a conduction inspection. If there is no conduction, replace the connector.
    • IOB (PCB17) – Drum motor (M6) connector
  • Drive transmission of the Drum motor (M6) defective
    Check the gears. If any gears are damaged, replace them.
  • Drum motor (M6) defective
    Replace the Drum motor (M6).
  • IOB (PCB17) defective
    Replace the IOB (PCB17).

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC396-02

D

Drum Motor (M6) Error 2

After the drum motor (M6) is stabilized, the stable OFF signal is detected for 2 seconds consecutively.

  • Connector disconnected or defective
  • Drive transmission of the Drum motor (M6) defective
  • Drum motor (M6) defective
  • IOB (PCB17) defective
  • Connector disconnected or defective
    Reconnect the following connector. Then perform a conduction inspection. If there is no conduction, replace the connector.
    • IOB (PCB17) – Drum motor (M6) connector
  • Drive transmission of the Drum motor (M6) defective
    Check the gears. If any gears are damaged, replace them.
  • Drum motor (M6) defective
    Replace the Drum motor (M6).
  • IOB (PCB17) defective
    Replace the IOB (PCB17).