SP No.

SP Name

Default Value

Factory Setting

SP1-001-001

Registration Correct: Main

+0.0 mm

-- mm*1

SP1-001-006

Registration Correct: By-Pass Tray

+0.0 mm

-- mm*1

SP1-001-007

Registration Correct: Duplex

+0.0 mm

-- mm*1

SP1-002-001

Registration Correct: Main

+0.0 mm

-- mm*1

SP1-002-006

Registration Correct: By-Pass Tray

+0.0 mm

-- mm*1

SP1-002-007

Registration Correct: Duplex

+0.0 mm

-- mm*1

SP4-011-001

S-to-S Regist Adjustment

+0.0 mm

-- mm*1

SP4-108-001

Sub Scan Speed.Adjustment

+0.0 %

-- %*1

SP4-110-001

L-Edge Timing Adjustment

+0 pulse

-- pulse*1

SP4-609-001

Gray Balance Set: R: Book Scan

-100 digit

-- digit*1

SP4-609-002

Gray Balance Set: R: DF Scan

-100 digit

-- digit*1

SP4-610-001

Gray Balance Set: G: Book Scan

-100 digit

-- digit*1

SP4-610-002

Gray Balance Set: G: DF Scan

-100 digit

-- digit*1

SP4-610-003

Gray Balance Set: BW: Book Scan

-100 digit

-- digit*1

SP4-610-004

Gray Balance Set: BW: DF Scan

-100 digit

-- digit*1

SP4-611-001

Gray Balance Set: B: Book Scan

-100 digit

-- digit*1

SP4-611-002

Gray Balance Set: B: DF Scan

-100 digit

-- digit*1

SP5-101-107

Auto Logout Timer: Auto Logout Time

1: Enable

0: Disable

SP5-305-101

Auto-Off Set: Set Function

1: Enable

0: Disable

SP5-748-201

OpePanel Setting: Cheetah Panel Connect Setting

0: Not connected

1: Connected

SP5-805-002

Drum Heater

NA/EU :0 (Off)

AP: 1 (ON)

NA/EU :0 (Off)

AP: 1 (ON)

SP5-875-001

SC Auto Reboot: Reboot Setting

0: The machine reboots automatically when the machine issues an SC error and logs the SC error code.

1: The machine does not reboot when an SC error occurs.

SP5-907-001

Plug&Play Maker/Model Name

0

0 or 9

(Set the appropriate setting for the model)

SP5-985-001

Device Setting: On Board NIC

0: Disable

1: Enable

SP5-985-002

Device Setting: On Board USB

0: Disable

1: Enable

SP6-006-001

ADF Adjustment: Side-to-Side Regist: Front

+0.0 mm

-- mm*1

SP6-006-002ADF Adjustment: Side-to-Side Regist: Rear+0.0 mm-- mm*1

SP6-026-001

ADF Timing Adjustment: Leading Edge Start Timing: Front

+0 pulse

-- pulse*1

SP6-026-002ADF Timing Adjustment: Leading Edge Start Timing: Rear+0 pulse-- pulse*1

SP6-026-003

ADF Timing Adjustment: Leading Edge End Timing: Front

-16 pulse

-- pulse*1

SP6-026-004

ADF Timing Adjustment: Leading Edge End Timing: Rear

-16 pulse

-- pulse*1

SP6-027-001

ADF Adjustment Scan Speed: Simplex Mode

+0.0 %

-- %*1

SP6-027-003

ADF Adjustment Scan Speed: Duplex Mode: Rear

+0.0 %

-- %*1

*1: This setting is specific to the machine type.