SP No. | SP Name | Default Value | Factory Setting |
---|---|---|---|
SP1-001-001 | Registration Correct: Main | +0.0 mm | -- mm*1 |
SP1-001-006 | Registration Correct: By-Pass Tray | +0.0 mm | -- mm*1 |
SP1-001-007 | Registration Correct: Duplex | +0.0 mm | -- mm*1 |
SP1-002-001 | Registration Correct: Main | +0.0 mm | -- mm*1 |
SP1-002-006 | Registration Correct: By-Pass Tray | +0.0 mm | -- mm*1 |
SP1-002-007 | Registration Correct: Duplex | +0.0 mm | -- mm*1 |
SP4-011-001 | S-to-S Regist Adjustment | +0.0 mm | -- mm*1 |
SP4-108-001 | Sub Scan Speed.Adjustment | +0.0 % | -- %*1 |
SP4-110-001 | L-Edge Timing Adjustment | +0 pulse | -- pulse*1 |
SP4-609-001 | Gray Balance Set: R: Book Scan | -100 digit | -- digit*1 |
SP4-609-002 | Gray Balance Set: R: DF Scan | -100 digit | -- digit*1 |
SP4-610-001 | Gray Balance Set: G: Book Scan | -100 digit | -- digit*1 |
SP4-610-002 | Gray Balance Set: G: DF Scan | -100 digit | -- digit*1 |
SP4-610-003 | Gray Balance Set: BW: Book Scan | -100 digit | -- digit*1 |
SP4-610-004 | Gray Balance Set: BW: DF Scan | -100 digit | -- digit*1 |
SP4-611-001 | Gray Balance Set: B: Book Scan | -100 digit | -- digit*1 |
SP4-611-002 | Gray Balance Set: B: DF Scan | -100 digit | -- digit*1 |
SP5-101-107 | Auto Logout Timer: Auto Logout Time | 1: Enable | 0: Disable |
SP5-305-101 | Auto-Off Set: Set Function | 1: Enable | 0: Disable |
SP5-748-201 | OpePanel Setting: Cheetah Panel Connect Setting | 0: Not connected | 1: Connected |
SP5-805-002 | Drum Heater | NA/EU :0 (Off) AP: 1 (ON) | NA/EU :0 (Off) AP: 1 (ON) |
SP5-875-001 | SC Auto Reboot: Reboot Setting | 0: The machine reboots automatically when the machine issues an SC error and logs the SC error code. | 1: The machine does not reboot when an SC error occurs. |
SP5-907-001 | Plug&Play Maker/Model Name | 0 | 0 or 9 (Set the appropriate setting for the model) |
SP5-985-001 | Device Setting: On Board NIC | 0: Disable | 1: Enable |
SP5-985-002 | Device Setting: On Board USB | 0: Disable | 1: Enable |
SP6-006-001 | ADF Adjustment: Side-to-Side Regist: Front | +0.0 mm | -- mm*1 |
SP6-006-002 | ADF Adjustment: Side-to-Side Regist: Rear | +0.0 mm | -- mm*1 |
SP6-026-001 | ADF Timing Adjustment: Leading Edge Start Timing: Front | +0 pulse | -- pulse*1 |
SP6-026-002 | ADF Timing Adjustment: Leading Edge Start Timing: Rear | +0 pulse | -- pulse*1 |
SP6-026-003 | ADF Timing Adjustment: Leading Edge End Timing: Front | -16 pulse | -- pulse*1 |
SP6-026-004 | ADF Timing Adjustment: Leading Edge End Timing: Rear | -16 pulse | -- pulse*1 |
SP6-027-001 | ADF Adjustment Scan Speed: Simplex Mode | +0.0 % | -- %*1 |
SP6-027-003 | ADF Adjustment Scan Speed: Duplex Mode: Rear | +0.0 % | -- %*1 |
*1: This setting is specific to the machine type.