Confirm that the DataOverwriteSecurity unit SD card is the correct type for the machine. The correct type for this machine is "Type M19".
- If you install any version other than "Type M19" for this machine, you will have to replace the NVRAM and do this installation procedure again.
- Make sure that the following settings are not at their factory default values:
- Supervisor login password
- Administrator login name
- Administrator login password
- Make sure that "Admin. Authentication" is ON.
[Settings] -> [Machine Features Settings] -> [System Settings] -> [Administrator Tools] -> [Administrator Authentication Management] -> [Admin. Authentication]
If this setting is OFF, tell the customer that this setting must be ON before you do the installation procedure. - Make sure that "Administrator Tools" is enabled (selected).
[Settings] -> [Machine Features Settings] -> [System Settings] -> [Administrator Tools] -> [Administrator Authentication Management] -> [Available Settings]
If this setting is disabled (not selected), tell the customer that this setting must be enabled (selected) before you do the installation procedure.
- See the operating instructions "Security" for the factory default values.