1. Display the NICE main menu. (How to Activate NICE)
  2. Press "Registration Adjustment" on the NICE main menu.
  3. Press "Select" to print out the test charts.

    • Adjustment is available only for trays associated with the custom paper library. Trays used under manual settings are grayed out and cannot be adjusted for registration.
    • 3 copies of the following chart will be printed in duplex along with a few blank sheets.

  4. Place the chart on a table, so that the side indicated "FIRST" [A] faces up and fold the 4 corners along the dotted lines as shown below. Do the same for the remaining 2 charts.
  5. Place the chart [A] on the exposure glass, so that the side indicated "SECOND" [B] faces up.
  6. Scan the "FIRST" side of all 3 charts. From the scanned data, the software application contained in the NICE SD card reads the distance [A] between the dotted lines along the folded edges and the paper edge on all 4 corners.
  7. On the table, fold the same 4 corners in reverse so that the corners appear on the side indicated "SECOND" [A]. Do the same for all 3 charts.
  8. Place the chart [A] on the exposure glass so that the side indicated "FIRST" [B] faces up.
  9. Scan the "SECOND" side of all 3 charts.
    With the measurements obtained in steps 6 and 9, SP values for front and back registration are corrected.
  10. Print out the trimming chart to check the results.
  11. Turn OFF the machine power and remove the NICE SD card from the service card slot.