- Display the NICE main menu. (How to Activate NICE)
- Press "Registration Adjustment" on the NICE main menu.
Press "Select" to print out the test charts.
- Adjustment is available only for trays associated with the custom paper library. Trays used under manual settings are grayed out and cannot be adjusted for registration.
- 3 copies of the following chart will be printed in duplex along with a few blank sheets.
- Place the chart on a table, so that the side indicated "FIRST" [A] faces up and fold the 4 corners along the dotted lines as shown below. Do the same for the remaining 2 charts.
- Place the chart [A] on the exposure glass, so that the side indicated "SECOND" [B] faces up.
- Scan the "FIRST" side of all 3 charts. From the scanned data, the software application contained in the NICE SD card reads the distance [A] between the dotted lines along the folded edges and the paper edge on all 4 corners.
- On the table, fold the same 4 corners in reverse so that the corners appear on the side indicated "SECOND" [A]. Do the same for all 3 charts.
- Place the chart [A] on the exposure glass so that the side indicated "FIRST" [B] faces up.
- Scan the "SECOND" side of all 3 charts.
With the measurements obtained in steps 6 and 9, SP values for front and back registration are corrected. - Print out the trimming chart to check the results.
- Turn OFF the machine power and remove the NICE SD card from the service card slot.