- Remove the exposure glass. (Exposure Glass)
- Remove the upper front cover. (Pro C5200S/C5210S: Upper Front Cover (Pro C5200S/C5210S), MP C6503/C8003: Upper Front Cover (MP C6503/C8003))
Move the 1st scanner carriage [A] to the notched section [B].
- Do not touch the mirror, reflector, or light guide plate in the scanner carriage.
Remove the exposure lamp (LED) [A] on the right side.
Remove the exposure lamp (LED) [A] on the left side.
- When attaching the exposure lamp, put the harness under the hook.
- When attaching the exposure lamp, put the harness under the hook.