When unpacking the machine, the ITB separation lever is not yet attached to the correct location. Be sure to attach the lever when installing the machine.

  1. Open the toner supply unit front cover [A], and remove the ITB separation lever [B].
  2. Open the drawer unit [A].
  3. Remove the drawer unit cover [A].
  4. Close the drawer unit.

      • Pushing the drawer unit back into the machine allows you to close the guide plate [A] of the paper exit and duplex unit after removing the drawer unit cover.
      • Make sure to hold down the lock lever [A] when pulling out the drawer unit. The drawer unit is locked in place by this lever.

  5. Remove the ITB cleaning intake fan [A] along with the duct.
  6. Open the toner supply unit front cover [A].
  7. Remove the fixing screws of the toner supply unit [A].

    • Do not remove the screw [B] below the toner supply unit fixing screw [A] because it is used to fix the faceplate.

  8. Slide the toner supply unit [A] to the front.
  9. Pull out the toner supply unit [A], and remove it from the slide rail with the handles on the left and right.

    • When attaching the toner supply unit [A] to the machine, the hooks of the toner supply unit should be fit into the holes in the slide rails.

  10. Remove the ITB retainer [A].
  11. Attach the ITB separation lever [A] horizontally from the right side of the machine.
  12. Turn the ITB separation lever [A] clockwise until it stops.
  13. Return the toner supply unit to the machine and secure it with the screws.
  14. Attach the ITB cleaning intake fan and drawer unit cover