SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC632-00 | D | Counter device error 1 |
After 3 attempts to send a data frame to the optional counter device via the serial communication line, no ACK signal was received within 100 ms. | ||
Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged. | ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC633-00 | D | Counter device error 2 |
After communication was established, the controller received the brake signal from the accounting device. | ||
Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged. | ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC634-00 | D | Counter device error 3 |
A backup RAM error was returned by the counter device. | ||
Counter device control board or the backup battery of counter device defective | ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC635-00 | D | Counter device error 4 |
A backup battery error was returned by the counter device. | ||
Counter device control board or the backup battery of counter device defective | ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC636-01 | D | IC Card Error (Expanded authentication module error) |
Issued when expanded authentication management is set to "ON" but either of the following occur.
| ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC636-02 | D | IC Card Error (Version error) |
The version of the expanded authentication module is not correct. | ||
Incorrect module version | ||
Install the correct file of the expanded authentication module. |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC637-01 | D | Tracking Information Notification Error (Tracking application error) |
Tracking information was lost. | ||
| ||
Turn the main power off/on. |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC637-02 | D | Tracking Information Notification Error (Management server error) |
Tracking information was lost. | ||
Communication with tracking management server failed.
| ||
Turn the main power off/on. |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC641-00 | D | Communication error between BICU and Controller board. |
Controller board does not respond after BICU tries to communicate three times. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC650-01 | C | Remote Service Modem Communication Error (Dialup authentication failure) |
| ||
Dialup authentication failure | ||
Check the following SPs.
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC650-04 | C | Remote Service Modem Communication Error (dialup failing because of incorrect modem configuration) |
| ||
Dialup failing because of incorrect modem configuration | ||
Check if the setting of SP5-816-160 is correct. If it is correct, then there is a software bug. |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC650-05 | C | Remote Service Modem Communication Error (insufficient current or connection fault) |
| ||
Insufficient current or connection fault | ||
The line is not supported and nothing can be done. |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC650-13 | C | Remote Service Modem Communication Error (RC Gate Type M was installed but modem is not present (detected during operation)) |
| ||
RC Gate Type M was installed but modem is not present (detected during operation) | ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC650-14 | C | Remote Service Modem Communication Error (RC Gate Type N was installed but modem is present or wired/wireless LAN is not working correctly) |
| ||
RC Gate Type N was installed but modem is present or wired/wireless LAN is not working correctly | ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC651-01 | C | Illegal Remote Service Dial-up (Chat program parameter error) |
An unexpected error occurred when RC Gate Type M dialed up the NRS Center. | ||
Software bug | ||
Logging only. |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC651-02 | C | Illegal Remote Service Dial-up (Chat program execution error) |
An unexpected error occurred when RC Gate dialed up the NRS Center. | ||
Software bug | ||
Logging only. |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC652-00 | A | Remote service ID2 mismatching |
There was an authentication mismatch between ID2 for @Remote, the controller board, and NVRAM. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC653-00 | A | Incorrect remote service ID2 |
ID2 stored in the NVRAM has either of the following problems.
| ||
Replace the NVRAM. | ||
Clear the RC Gate install status, write the common certificate, and then begin installation again. |
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC670-01 | D | Engine start up error when the machine boots up |
| ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC670-02 | D | Engine start up error when the machine is in operation |
| ||
Engine board reset unexpectedly. | ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC670-03 | D | BICU start up error when the machine boots up |
VDET_EPCI signal was not asserted when the machine was turned on. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC670-04 | D | Communication error between the engine and controller |
Communication could not linked up. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC672-00 | D | Controller start up error |
After the machine was powered on, communication between the controller and the operation panel was not established, or communication with controller was interrupted after a normal startup. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC672-01 | D | Controller start up error |
After the machine was powered on, communication between the controller and the operation panel was not established. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC672-02 | D | Controller start up error |
Communication between the controller and the operation panel was interrupted after a normal startup. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC672-03 | D | Controller start up error |
For a reason except SC672-00 to 02 mentioned above, the controller down is detected on the operation panel. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC672-10 | D | Controller start up error |
After the machine was powered on, communication between the controller and the operation panel was not established. | ||
| ||
When LED8 (red) on the controller board does not flicker:
When LED8 (red) on the controller board flickers:
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC672-11 | D | Controller start up error |
After the machine was powered on, communication between the controller and the operation panel was not established, or communication with controller was interrupted after a normal startup. | ||
| ||
When LED8 (red) on the controller board does not flicker:
When LED8 (red) on the controller board flickers:
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC672-12 | D | Controller start up error |
Communication with controller was interrupted after a normal startup. | ||
| ||
When LED8 (red) on the controller board does not flicker:
When LED8 (red) on the controller board flickers:
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC672-13 | D | Controller start up error |
The operation panel detected that the controller is down. | ||
| ||
When LED8 (red) on the controller board does not flicker:
When LED8 (red) on the controller board flickers:
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC672-99 | D | Controller start up error |
The operation panel software ended abnormally. | ||
| ||
When LED8 (red) on the controller board does not flicker:
When LED8 (red) on the controller board flickers:
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC673-10 | D | Flair connection error of Smart Operation Panel |
The SC is issued only when the Smart Operation Panel is installed. The main machine does not respond to the smart operation panel with the Flair communication. | ||
The SP setting for the smart operation panel is mismatched. | ||
Note for the phone number. |