This section describes the procedure for attaching the Wide Guide Sheet to the entrance guide that was removed in step 5. (Removing the Entrance Guide)
[A]: Wide Guide Sheet (50mm, accessories item #6)
[A]: Upper entrance guide
[B]: Lower entrance guide
Attaching the Wide Guide Sheet to the Upper Entrance Guide
- Peel off the release paper from the double-sided tape [C] on the Wide Guide Sheet.
Attach the Wide Guide Sheet to the upper entrance guide by aligning the edge [D] of the Guide Sheet with the edge (1) of the guide plate, and the shorter edge [E] of the Guide Sheet with the edge (2) of the guide plate.
- The alignment position of edge [E] is different from when connecting the buffer pass unit to the mainframe.
- Confirm that the Wide Guide Sheet is attached correctly to the upper entrance guide as shown in the photo below.
Attaching the Wide Guide Sheet to the Lower Entrance Guide
- Peel off the release paper from the double-sided tape [C] on the Wide Guide Sheet.
Attach the Wide Guide Sheet to the lower entrance guide by aligning the edge [D] of the Guide Sheet with the edge (1) of the guide plate, and edge [E] of the double-sided tape with the edge (2) of the guide plate.
- Same as when connecting buffer pass unit to the mainframe.
- Confirm that the Wide Guide Sheet is attached correctly to the lower entrance guide as shown in the photo below.
- Reattach the entrance guide to the buffer pass unit.
Connecting the Buffer Pass Unit
- Reattach the right cover of the buffer pass unit.
- Remove the rear upper cover [A] of the Decurl Unit.
- Remove the lower rear cover [A] of the Decurl Unit.
- Remove the bracket [A] from the Decurl Unit.
- Attach the right connecting bracket [A] (accessories item #5) and left connecting bracket [B] (accessories item #4) to the paper exit side of the Decurl Unit.
- Connect the I/F cable of the Decurl Unit to the socket [A] of the mainframe. Then connect the Buffer Pass Unit with the Decurl Unit similarly to steps 4 through 6 of #01: When Connecting the Buffer Pass Unit with the Mainframe.
- Go to Common Procedure.