This section describes the procedure for attaching the Wide Guide Sheet to the entrance guide that was removed in step 5. (Removing the Entrance Guide)

[A]: Wide Guide Sheet (50mm, accessories item #6)

[A]: Upper entrance guide

[B]: Lower entrance guide

Attaching the Wide Guide Sheet to the Upper Entrance Guide
  1. Peel off the release paper from the double-sided tape [C] on the Wide Guide Sheet.
  2. Attach the Wide Guide Sheet to the upper entrance guide by aligning the edge [D] of the Guide Sheet with the edge (1) of the guide plate, and the shorter edge [E] of the Guide Sheet with the edge (2) of the guide plate.

    • The alignment position of edge [E] is different from when connecting the buffer pass unit to the mainframe.

  3. Confirm that the Wide Guide Sheet is attached correctly to the upper entrance guide as shown in the photo below.
Attaching the Wide Guide Sheet to the Lower Entrance Guide
  1. Peel off the release paper from the double-sided tape [C] on the Wide Guide Sheet.
  2. Attach the Wide Guide Sheet to the lower entrance guide by aligning the edge [D] of the Guide Sheet with the edge (1) of the guide plate, and edge [E] of the double-sided tape with the edge (2) of the guide plate.

    • Same as when connecting buffer pass unit to the mainframe.

  3. Confirm that the Wide Guide Sheet is attached correctly to the lower entrance guide as shown in the photo below.
  4. Reattach the entrance guide to the buffer pass unit.
Connecting the Buffer Pass Unit
  1. Reattach the right cover of the buffer pass unit.
  2. Remove the rear upper cover [A] of the Decurl Unit.
  3. Remove the lower rear cover [A] of the Decurl Unit.
  4. Remove the bracket [A] from the Decurl Unit.
  5. Attach the right connecting bracket [A] (accessories item #5) and left connecting bracket [B] (accessories item #4) to the paper exit side of the Decurl Unit.
  6. Connect the I/F cable of the Decurl Unit to the socket [A] of the mainframe. Then connect the Buffer Pass Unit with the Decurl Unit similarly to steps 4 through 6 of #01: When Connecting the Buffer Pass Unit with the Mainframe.
  7. Go to Common Procedure.