- If the Buffer Pass Unit is to be connected to the Decurl Unit DU5020 (D727), go to " #02: When Connecting the Buffer Pass Unit with the Decurl Unit DU5020 (D727)".
This section describes the procedure for attaching the Wide Guide Sheet to the entrance guide plate that was removed in step 5.(Removing the Entrance Guide)
[A]: Wide Guide Sheet (50mm, accessory item #6)
[A]: Upper entrance guide plate
[B]: Lower entrance guide plate
Attaching the Wide Guide Sheet to the Upper Entrance Guide Plate
- Peel off the release paper from the double-sided tape [C] on the Wide Guide Sheet.
- Attach the Wide Guide Sheet to the upper entrance guide plate by aligning the edge [D] of the Guide Sheet with the edge (1) of the upper entrance guide plate, and edge [E] of the double-sided tape with the edge (2) of the upper entrance guide plate.
- Confirm that the Wide Guide Sheet is attached correctly to the upper entrance guide plate as shown in the photo below.
Attaching the Wide Guide Sheet to the Lower Entrance Guide Plate
- Peel off the release paper from the double-sided tape [C] on the Wide Guide Sheet.
- Attach the Wide Guide Sheet to the lower entrance guide plate by aligning the edge [D] of the Guide Sheet with the edge (1) of the lower entrance guide plate, and edge [E] of the double-sided tape with the edge (2) of the lower entrance guide plate.
- Confirm that the Wide Guide Sheet is attached correctly to the lower entrance guide plate as shown in the photo below.
- Reattach the entrance guide plate to the buffer pass unit.
Connecting the Buffer Pass Unit
- Reattach the right cover of the buffer pass unit.
- Attach the sponge strip [A] (accessories item #8) to the Buffer Pass Unit as shown in the illustration below.
- Attach the right connecting bracket [A] (accessories item #5) and left connecting bracket [B] (accessories item #4) to the main frame.
- Remove the connector cover [A] from the mainframe.
- Open the front door, then pull out the locking lever [A].
- Push the buffer pass unit against the mainframe to dock the units.
- Push the lock lever [A] and fasten it with the screw removed in step 5.
- Connect the I/F cable of the buffer pass unit to the socket [A] on the mainframe.
Go to Common Procedure.