Before you start:
- Clear the counter for the ITB in PM counter mode (or use SP mode to turn SP3701-093 or 094 “0
1”)
- Turn the machine off.
- Remove the ITB unit. (ITB Unit Removal)
- Remove both side brackets [A], [B].
- Remove the anti-toner-scattering cover [A].
- Remove the stay [A] on the left side.
- Remove the stay [A] on the right side.
- Remove the bracket with ID/MUSIC sensors [A].
- Remove the center stay [A].
- Hold the frames [A] of the encoder roller and pull them towards you.
- Remove the bracket [A]. Remove the tension roller [B].
Pull the transfer belt [A] upward to remove it.
- Be sure to install the new transfer belt with the number at the rear of the machine (the lower side in the picture below).
- Be sure to attach the new transfer belt without slackness.
- After the replacement, some procedures need to be done. See “Lubrication after replacement” described below.