Do not replace the drum cleaning unit or the drum cleaning blade at the same time as the following parts.
- ITB
- ITB Cleaning Unit
- ITB Cleaning Blade (ITB Cleaning Unit Component)
- ITB Lubricant Bar (ITB Cleaning Unit Component)
- ITB Lubricant Blade (ITB Cleaning Unit Component)
After replacing the drum cleaning unit or the drum cleaning blade, cleaning initial setting is performed automatically. On the other hand, after replacing the above five parts, you need to run SP2-696-001 (Force Apply Lubricant Execute) manually before cleaning initial setting runs. (Lubrication after replacement). This is because, if cleaning initial setting runs automatically before running SP2-696-001 (Force Apply Lubricant Execute) manually, the ITB cleaning blade will be turned up.
If you need to replace the above five parts at the same time as replacing the drum cleaning unit or the drum cleaning blade, use the following procedure.
- In the PM counter screen, set "New Part Set" to ON for the drum cleaning unit or the drum cleaning blade.
- Replace the drum cleaning unit or the drum cleaning blade. (The cleaning initial setting automatically runs)
- In the PM counter screen, set "New Part Set" to ON for the above five parts.
- Replace the above five parts.
- Enter the SP mode and run SP2-696-001 (Force Apply Lubricant Execute) manually.