Install the relay duct and swinging plate using the following procedure.

  1. Remove the relay duct seal [A] and hook the cutout [B] onto the relay duct [C].

  2. Attach the relay duct [A] to the waste toner bottle unit, and drop the swinging plate [B] into the unit.

  3. Clean the attachment surface with alcohol and attach a seal [A].