1. Remove the drawer unit cover. (Drawer Unit Cover)
  2. Remove the fusing unit. (Removing the Fusing Unit)
  3. Remove the bracket [A] of the cleaning web contact sensor.
  4. Remove the cleaning web contact sensor [A].

    • Rotate the cleaning web motor [A] counter-clockwise, to make a space in the drawer unit to remove the cleaning web contact sensor.