1. Set the leveling shoes [A] and adjust the height of the unit.
  2. Remove the 2 screws [A] on the front side of clamping bracket [D].
  3. Turn the Kc5 lever [B] counter clockwise and pull out the buffer pass unit drawer [C].
  4. Remove the clamping bracket [D].
  5. Remove the 4 shipping brackets [E].
  6. Slide in the buffer pass unit drawer [C].
  7. Close the front door [F].
  8. Attach the connecting bracket [A] of the downstream device to the left side of the buffer pass unit. (The illustration below is an example showing the bracket for SR4110.)
  9. Attach the Narrow Guide Sheet [A] (35.5mm, accessories item #7) to the entrance guide of the downstream device (for example, the SR4110) by referring to the procedure in the following section.
Attaching the Narrow Guide Sheet to the Upper Entrance Guide
  1. Peel off the release paper from the double-sided tape [A] on the Narrow Guide Sheet.
  2. Attach the Narrow Guide Sheet to the upper entrance guide by aligning the edge [B] of the double-sided tape with the edge (1) of the guide plate, and the edge [C] of the double-sided tape with the edge (2) of the guide plate.
  3. Confirm that the Narrow Guide Sheet is attached correctly to the upper entrance guide as shown in the photo below.
Attaching the Narrow Guide Sheet to the Lower Entrance Guide
  1. Peel off the release paper from the double-sided tape [A] on the Narrow Guide Sheet.
  2. Attach the Narrow Guide Sheet to the lower entrance guide by aligning the edge [B] of the Guide Sheet with the edge (1) of the guide plate, and edge [C] of the double-sided tape with the edge (2) of the guide plate.
  3. Confirm that the Narrow Guide Sheet is attached correctly to the lower entrance guide as shown in the photo below.
Completing the Installation
  1. Dock the downstream device to the buffer pass unit.
  2. Connect the power cord [A] provided with the buffer pass unit to the power inlet on the buffer pass unit.
  3. Connect the buffer pass unit power cord to the wall socket, and then connect the mainframe power cord to the wall socket.

    • Make sure the power cords are plugged into the wall sockets in the above order. Otherwise, the buffer pass unit will not be recognized by the mainframe when turning on the power in the following step, and this will cause a paper jam in the buffer pass unit.

  4. Turn ON the main power switch on the mainframe.