When installing this option, turn OFF the main power and unplug the power cord from the wall socket. If installing without turning OFF the main power, an electric shock or a malfunction may occur.

The USB device server option has an IP address stored on the PCB. This is different from the machine's IP address. The IP address and other network settings of the USB device server option must be configured after installing this option.

  1. Turn OFF the main power of the machine, and unplug the power cord from the wall socket.
  2. Remove the cover [A].
  3. Remove the slot cover [A] from the I/F slot B.

    • The USB Device Server Option Type M19 can be connected to either of I/F slot A and B.

  4. Insert the interface board [A] into the slot.
  5. Insert the USB cable [A] into the USB port (Type A) on the machine I/F.
  6. Insert the other side of the USB cable [B] into the USB port (Type B) on this option board.
  7. Attach the ferrite cores to the Ethernet cable, while looping the cable at 3 cm (approx. 1.2 inch) [A] from each end of the cable.
  8. Only for installing this option in North America, bind both cores with cable ties [A] as shown below.
  9. Insert the Ethernet cable [A] into the Ethernet port on this option.
  10. Insert the other end of the Ethernet cable to a PC for network setting.
  11. Plug the power cord into the wall socket and turn on the main power of the machine.

    Do not unplug the USB cable while the machine is recognizing this option. It may take between 30 seconds to 1 minute to finish recognizing it (the LEDs on the Ethernet port of this option light up after recognizing this option; see below). If unplugged, connect the cable again.

  12. Make sure that the machine recognizes this option correctly by doing one of the following:

    1. Access the option’s IP address from a web browser.
    2. Ping the option’s IP address from a command prompt on a Windows PC in the same network as the mainframe. If the IP address cannot be found (DHCP server), use the MAC address. This is the number printed on the seal attached to the printed circuit board for the USB server.
    3. Use "RX" + the option’s MAC address and access a web browser. Example: http://RX0080926A3264
    4. Ping "RX" + "MAC address" from the command prompt on a windows PC which is on the same network as the mainframe.

  • When installing the USB Device Server Option Type M19, the installation status is not shown on the Configuration Page.
  • The customer should keep the slot covers which were removed.

What Do the LED Indications Mean?

When this option is properly installed and recognized by the main machine, the LED indicators light up under the following conditions.

No.Light ColorLights Up When
1Green and Yellow1000BASE-T operates
2Green10BASE-T operates
3Yellow100BASE-TX operates
Notes for Energy Save Mode Setting

If the machine which has this option enters into the energy save mode, you cannot print because there will be a communication error. Follow the instructions below to disable the machine’s entering into the energy save mode.

  1. Enter SP mode, and then set SP5-191-001 (Power Setting: Power Str) to "0 (Off)".