Plug in the power cord, and then turn ON the main power switch.
Enter the SP mode, and note the following SP values.
- SP2-104-040 (Skew Adjustment: Manual: K: CE)
- SP2-104-041 (Skew Adjustment: Manual: K: User)
- SP2-104-002 (Skew Adjustment: Manual: C)
- SP2-104-003 (Skew Adjustment: Manual: M)
- SP2-104-004 (Skew Adjustment: Manual: Y)
- Set the following SP values to "0".
- SP2-104-040 (Skew Adjustment: Manual: K: CE)
- SP2-104-041 (Skew Adjustment: Manual: K: User)
- SP2-104-002 (Skew Adjustment: Manual: C)
- SP2-104-003 (Skew Adjustment: Manual: M)
- SP2-104-004 (Skew Adjustment: Manual: Y)
- If you do not do the above adjustment, MUSIC may not work. This is because one or more of the motors may be at or near the upper or lower limit (± 100). In such a case, if you do not zero the motor positions before MUSIC is done, the range that the motor can move will be restricted and the adjustment may not be done correctly.
- Enter the SP mode, and set the following SPs.
- SP2-102-001 (Magnification Adjustment: Main Mag.: K): set to "123" (for the CK laser unit)
- SP2-102-007 (Magnification Adjustment: Main Mag.: M): set to "123" (for the YM laser unit)
- SP2-102-016 (Magnification Adjustment: Main/Sub: K): set to "0"
- SP2-102-019 (Magnification Adjustment: Main/Sub: C): set to "0"
- SP2-102-022 (Magnification Adjustment: Main/Sub: M): set to "0"
- SP2-102-025 (Magnification Adjustment: Main/Sub: Y): set to "0"
- For the Magnification Adjustment values of SP2-102-001/007, set to "123" only for the color of the new laser unit.
- For the Magnification Adjustment values of SP2-102-016 through 025, set to "0" only for the color of the new laser unit.