Symptom

One or more white lines appear along the paper feed direction.

Cause 1

Dirty dust shield glass and/or clogged doctor gap.

 Dirty dust shield glassClogged doctor gap
Symptom in detail1 or more lines of 0.1 to 1 mm width appear along the feed direction across the entire page.
Cause in detailToner, lubricant, etc. on the dust shield glass block the laser beam exposed on the drum.

Doctor gap is clogged with foreign substances/clumps of developer, disabling sufficient transport of developer to the development roller.

Solution

Clean the dust shield glass.

Clean the doctor blade / Replace the developer / Extend the fan operation time setting in the SP mode / Replace the development unit.

[A]: White line

[B]: Feed direction

Cause 2

Foreign substance in the development unit.

Symptom in detail1 or 2 lines of 0.1 to 0.5 mm width appear at approximately 5 to 10 mm from the leading edge.
Cause in detailImage developed on the drum is scraped off by a foreign substance stuck between the development roller and the drum.
SolutionRemove the foreign substance.

[A]: White line

[B]: Approximately 5 to 10 mm from leading edge

[B]: Feed direction

Flow Chart

Step 1

 

Step 2

*1 See Doctor Gap for details about the cleaning procedure.

Step 3