If the downstream device is Finisher SR4120, Booklet Finisher SR4130, Finisher SR5070, or Booklet Finisher SR5080
  1. Attach the following to the decurl unit.
    [A]: Right connecting bracket (M4x8)
    [B]: Left connecting bracket (M4x8).

If the downstream device is Cover Interposer Tray CI4040 or Cover Interposer Tray CI4020
  1. Install the small bracket [A] on the cover interposer tray [B].
  2. Connect the downstream device.
If the downstream device does not have a connecting section (such as Buffer Pass Unit Type S6)
  1. Remove the rear upper cover [A] of the decurl unit.
  2. Remove the rear lower cover [A] of the decurl unit.
  3. Remove the connecting bracket [A].
  4. Connect the downstream device.

    • When you remove the decurl unit, hold it in the lower half, lower than the middle.