Do this check to detect the presence of skew in the paper path.

  1. Make sure that the I/F cable of the unit is connected to the upstream device.
  2. If a peripheral unit is connected on the left side, disconnect it and pull it away.
  3. Execute a straight-through run.
  4. Check the scale where each sheet exits.
    • The rear scale is for DLT-size paper.
    • The front scale [2] is for A3-size paper.
    • Be sure to read the correct scale for the paper size in use.

      [A]

      Centered. No adjustment necessary.

      [B]

      Trailing edge skew to the front, total skew more than ±2 mm. Adjustment required.

      [C]

      Trailing edge skew to the rear, total skew more than ±2 mm. Adjustment required.