In the SP mode, there is a management screen for the PM counter.
Enter the SP mode.
Press [PM Counter/New Unit Set].
Select the item you want to configure.
[1] All PM Parts List: New Unit Set
Displays all PM items (all PM items, not only PM units). Lists all PM items regardless of PM yield indicator settings.
[2] Parts List for PM yield indicator: New Unit Set
Displays only the items with their PM yield indicator settings set to "Yes".
[3] Clear all PM settings
Resets all PM counter settings to "0" at the same time. PM items can be reset one by one in the "All PM Parts List: New Unit Set" menu.
[4] Counterlist print out
Prints the PM counter on paper.
[5] Estimated usage ratio/Remain Days: New Unit Set
Displays the estimated usage ratio (0 to 100%) and remaining days (255 to 0 days) of the PM items, in which the calculation is based on page counter value and running distance, allowing more accuracy in comparison to the conventional PM page counter.
[6] Commissioning Status Report Print
Prints the status report.