1. Remove the fusing unit. (Removing the Fusing Unit)

  2. Remove the cover [A].
  3. Remove the separation pawl [A].
  4. Remove the guide plate [A].
  5. Wipe the inverter feed roller (drive/idle) with a damp cloth.


    • [A]: Inverter feed roller (Drive)

    • [B]: Inverter feed roller (Idle)

    • Before you wipe the inverter feed roller (idle), squeeze the damp cloth very tightly.