SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-10  | D  | Upper Transport Motor Error (Finisher SR4110)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-14  | B  | Lower Transport Motor Error (Finisher SR4110)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-15  | B  | Pre-stack Transport Motor Error (Finisher SR4110)  | 
SC722-16  | D  | Upper Tray Exit Motor Error (Finisher SR4110)  | 
SC722-17  | B  | Shift Tray Exit Motor Error (Finisher SR4110)  | 
SC722-18  | B  | Stapler Exit Motor Error (Finisher SR4110)  | 
Motor driver detected an open circuit or short-circuit. (SC from the first time)  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-20  | D  | Upper Tray Junction Gate Motor Error (Finisher SR4110)  | 
SC722-21  | D  | Stapler Junction Gate Motor Error (Finisher SR4110)  | 
SC722-22  | B  | Pre-stack Junction Gate Motor Error (Finisher SR4110)  | 
SC722-23  | B  | Pre-stack Paper Stopper Motor Error (Finisher SR4110)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-24  | B  | Exit Guide Motor Error (Finisher SR4110)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-25  | D  | Punch Motor Error (Finisher SR4110)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-30  | B  | Jogger Motor Error (Finisher SR4110)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-33  | B  | Positioning Roller Motor Error (Finisher SR4110)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-34  | B  | Positioning Roller Transport Motor Error (Finisher SR4110)  | 
Motor driver detected an open circuit or short-circuit. (SC from the first time)  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-35  | B  | Stack Plate-Center Motor Error (Finisher SR4110)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-36  | B  | Stapler Plate-Front Motor Error (Finisher SR4110)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-37  | B  | Stapler Plate-Rear Motor Error (Finisher SR4110)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-39  | B  | Stapler Movement Motor Error (Finisher SR4110)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-40  | B  | Stapler Rotation Motor Error (Finisher SR4110)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-41  | B  | Stack Feed-Out Belt Motor Error (Finisher SR4110)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-42  | B  | Stapler Motor Error (Finisher SR4110)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-43  | B  | Stapler Rotation Motor Error (Finisher SR4110)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-44  | B  | Stapler Hammer Motor Error (Finisher SR4110)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-70  | B  | Shift Tray Lift Motor Error (Finisher SR4110)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-71  | B  | Shift Motor Error (Finisher SR4110)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-72  | B  | Shift Jogger Motor Error (Finisher SR4110)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-74  | B  | Shift Jogger Lift Motor Error (Finisher SR4110)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-75  | B  | Return Drive Motor Error (Finisher SR4110)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC722-76  | B  | Stacking Roller Motor Error (Finisher SR4110)  | 
Motor driver detected an open circuit or short-circuit. (SC from the first time)  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC725-01  | D  | Downstream device communication error (Multi-Folding Unit)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC725-12  | B  | Reg. Roller Transport Motor Error (Multi-Folding Unit)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC725-13  | B  | Dynamic Roller Transport Motor Error (Multi-Folding Unit)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC725-14  | B  | Z-fold top tray exit motor error (Multi-Folding Unit)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC725-30  | B  | Z-fold stopper 1 Motor error (Multi-Folding Unit)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC725-31  | B  | 2nd Stopper Motor Error (Multi-Folding Unit)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC725-32  | B  | 3rd Stopper Motor Error (Multi-Folding Unit)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC725-33  | B  | Jogger Fence Motor Error (Multi-Folding Unit)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC725-34  | B  | Dynamic Roller Lift Motor Error (Multi-Folding Unit)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC725-35  | B  | Registration Roller Release Motor Error (Multi-Folding Unit)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC725-36  | B  | FM2 Direct-Send JG Motor Error (Multi-Folding Unit)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC725-37  | B  | FM6 Pawl Motor Error (Multi-Folding Unit)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC725-38  | B  | Fold Plate Motor Error (Multi-Folding Unit)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC725-39  | B  | 1st Fold Motor Error (Multi-Folding Unit)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC725-40  | B  | 2nd Fold Motor Error (Multi-Folding Unit)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC725-41  | B  | Crease Motor Error (Multi-Folding Unit)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC725-71  | D  | Horizontal Transport Motor Error (Multi-Folding Unit)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC725-72  | D  | Horizontal exit motor error (Multi-Folding Unit)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC725-73  | D  | Horizontal exit motor error (Multi-Folding Unit)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC725-74  | D  | Entrance JG Motor Error (Multi-Folding Unit)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC740-01  | D  | Downstream device communication error (Cover Interposer Tray CI4020)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
| SC740-03 | D | Protection Device Break Error 1 (Cover Interposer Tray CI4040) | 
| Protection device break error (fuse tripped, 24V tripped) | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC740-10  | B  | Bottom Plate Lift Motor Error (Cover Interposer Tray CI4040)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC740-10  | B  | 1st Lift Motor Error (Cover Interposer Tray CI4020)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC740-11  | B  | 1st Pick-Up Motor Error (Cover Interposer Tray CI4020)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC740-20  | B  | 2nd Lift Motor Error (Cover Interposer Tray CI4020)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC740-21  | B  | 2nd Pick-Up Motor Error (Cover Interposer Tray CI4020)  | 
  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC745-03  | D  | Protection device break error 1 (Mailbox)  | 
Protection device break error (fuse tripped)  | ||
  | ||
  | 
SC No.  | Level  | Error Name/Error Condition/Major Cause/Solution  | 
|---|---|---|
SC780-50  | B  | LCIT high efficiency controller communication error (LCIT RT4020/RT4050)  | 
An error was detected during read/write access in SPI communication between SPU and high-efficiency controller.  | ||
  | ||
  |