- Remove the ITB cleaning intake fan. (ITB Cleaning Intake Fan)
- Release the lock lever [A].
Pull the ITB cleaning unit [A] out.
- When re-installing the ITB cleaning unit in the machine, pay attention to the following.
- Ensure that the lock lever is unlocked.
- Lift and set the ITB cleaning unit to put the two positioning pins into the unit.
- Do not peel off the side seals [A]. Take care not to touch the side seals [A] and the plate [B], because the side seals [A] might peel off.
- When re-installing the ITB cleaning unit in the machine, pay attention to the following.