- Remove the upper right cover. (Upper Left Cover, Upper Right Cover)
- Cover the exposure glass [A] to protect it.
- Open the toner supply unit front cover.
- Remove the screws and clamps of the lower cover [A].
- Turn over the operation panel [A] and the lower cover [B] towards the scanner.
Disconnect the USB connector and the grounding wire of the operation panel [A].
- When you disconnect or connect the USB cable, hold the connector part of the cable.
- Remove the harnesses from the harness guide.
Remove the lower cover [A].
- Remove the operation panel [A].
Before you replace the operation panel, make sure that DIP switches 3 and 7 of the new operation panel are set to ON.
- If the DIP switch settings are not correct, the machine will issue SC672.