After installing the new fusing unit for Pro C5200S/C5210S, adjust the nip width of the fusing unit with the following procedure.
- Open the drawer unit [A].
- Check the label [B] attached to the fusing front cover [A].
The adjustment value for the fusing nip width is printed on the label. - Take a note of the first half of the number [A] and the second half of the number [B] on the label.
- Slide the drawer unit back in.
- Display the "Machine Features" screen.
- When using the standard operation panel: Press the "User Tools" key.
- When using the smart operation panel: Press the "User Tools" icon, and then press "Machine Features".
- Display the "Adjustment Settings for Operators" screen.
- Press "Adjustment Settings for Operators".
- Enter the user name in the user name entry screen.
- Enter the password in the password entry screen.
- Press "02 Machine: Image Quality", and then press "0212: Slope for Envelope Nip Width".
- Enter the first half [A] of the number on the label, in "02: Coefficient of Linear Function: I".
- Enter the second half [B] of the number on the label, in "03. Constant Term: m".