After installing the new fusing unit for Pro C5200S/C5210S, adjust the nip width of the fusing unit with the following procedure.

  1. Open the drawer unit [A].
  2. Check the label [B] attached to the fusing front cover [A].
    The adjustment value for the fusing nip width is printed on the label.
  3. Take a note of the first half of the number [A] and the second half of the number [B] on the label.
  4. Slide the drawer unit back in.
  5. Display the "Machine Features" screen.
    • When using the standard operation panel: Press the "User Tools" key.
    • When using the smart operation panel: Press the "User Tools" icon, and then press "Machine Features".
  6. Display the "Adjustment Settings for Operators" screen.
    1. Press "Adjustment Settings for Operators".
    2. Enter the user name in the user name entry screen.
    3. Enter the password in the password entry screen.
  7. Press "02 Machine: Image Quality", and then press "0212: Slope for Envelope Nip Width".
  8. Enter the first half [A] of the number on the label, in "02: Coefficient of Linear Function: I".
  9. Enter the second half [B] of the number on the label, in "03. Constant Term: m".