1. Remove the exposure glass (Exposure Glass)

  2. Clean the front and back of the exposure glass with a glass cleaner.

  3. Open the ADF exposure glass [A] from its left side, and then clean the front and back of the ADF exposure glass with a glass cleaner.

  4. First, turn the gear [A] and move the 1st scanner carriage [B] to the center.

    • Do not touch the mirror or light guide plate in the scanner carriage.

  5. Clean the 1st mirror [A], 2nd mirror [B] and 3rd mirror [C] with a dry optical cloth.

  6. Clean the original size sensors [A] with a dry cloth.