When replacing, apply the lubricant powder (D0159501) (zinc stearate) to the OPC drum evenly with a brush.
- Use the blower brush (D0747690) when applying lubricant powder (zinc stearate) to the OPC drum.
- Use the blower brush (D0747690) when applying lubricant powder (zinc stearate) to the OPC drum.
- Remove the protective sheet (black) [B] from around the new OPC drum and lay it on the development unit [A].
Attach the new OPC drum [A] and remove the protective sheet (black) [B] from the bottom.
- The surface of a newly replaced drum needs to be lubricated. In the lubrication process where the drum is manually rotated, the two drum holders [A] fix the shaft so that the drum rotates precisely on its axis.
- Attach the drum holders [A] to the front and rear sides of the drum [B].
- Make sure the drum holders are inserted all the way in. Hold the flange [C] and rotate the drum in the direction of the development unit [D].
- The two drum holders [A] are accessory parts of the machine.