Press any number button to open the sub menu for a part. In the example below, the number button [003: #Development Unit: K] was pressed.

[A]: New Unit Set
Press [Yes] to reset the selected PM counter (in this example 003 #Development Unit: K) to "0". You can also clear the settings by pressing the [No] button on the right side of the PM Counter Main Menu ([F] in the previous section).

[B]: Change target yield
Press to change the target PM yield. To change the setting:

  • Press [Change target yield]

  • Enter the number for the new target with the 10-key pad.

  • Press [#].

[C]: PM yield indicator settings
[Yes] is the default. Press [No] to remove the current item from the "Parts list for PM yield indicator : New Unit Set" menu.

  • When set to "Yes", items marked with the # mark (# = a unit) will not have their individual items displayed automatically in the "Parts list for PM yield indicator list".

  • When set to "No", items marked with the # mark (# = a unit) only the individual components will appear in the list (the units will not appear).

[D]: PM counter history
This is a summary of the most recent counts

  • Latest 1. The latest PM count since the unit (or part) was replaced.

  • Latest 2. The previous PM count since the unit (or part) was replaced.

  • Latest 3. The previous but one PM count since the unit (or part) was replaced.