- Remove the drawer unit cover. (Drawer Unit Cover)
In order to facilitate the work, pull the drawer unit out half way, then press the release levers (one on the left side and one on the right side, shown by the red arrows) and pull the drawer unit [A] out fully.
- In a low-temperature environment (below 15°C), the tension of the curled cord may be reduced. So, do not pull the drawer unit out for a long time, or the curled cord will be deformed and will not curl up again when you try to slide the drawer unit back in. As a guide, every 30 minutes, push the drawer unit back to the half-way position. There is no decrease in tension of the curled cord with a low-temperature environment if the drawer unit is open halfway.
- Remove the inner cover [A].
- Open the heat pipe cover [A].*
*For Pro C5200S/C5210S, use a TCRU screw. - Remove the fixing screws on the front side of the fusing unit [A].*
*For Pro C5200S/C5210S, use TCRU screws. - Open the guide plate [A].
- Lift the guide plate [A] up.
- Hold the handgrips to detach the fusing unit [A].