SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|
SC685-05 | B | PFB 24V Power Supply Voltage Error 1 |
| | Tracks for 2.5 second (timeout) from the time the HAISHI_FAN_O is turns ON on the software. |
| | - PSU malfunctioning
- Connecter disconnected
- Harness broken or ground fault
- Fans for Booklet Finisher SR4130/Finisher SR4120 (Cooling Fan Unit Type M26) malfunctioning
- PFB malfunctioning
|
| | - Check whether the power supply LED (LED4) on the PFB is lit to yellow.
- LED4 is lit: execute step 2.
- LED4 is not lit: execute step 2 and then step 3.
- Check and replace the harnesses of the PFB and PSU1 if they are broken or have defective grounding. Then, turn the machine OFF/ON to check the SC occurrence.
- The SC occurred: execute step 4 (or 3).
- Reconnect the cables of the PFB and PSU2. Then, turn the machine OFF/ON to check the SC occurrence.
- The SC occurred: execute step 5.
- Replace the PFB. Then, turn the machine OFF/ON to check the SC occurrence.
- The SC occurred: execute step 5.
- Replace the PSU2. Then, turn the machine OFF/ON to check the SC occurrence.
- The SC did not occur: check the fan for Booklet Finisher SR4130/Finisher SR4120 (Cooling Fan Unit Type M26) with the OUTPUT command in SP mode.
|