SC No.LevelError Name/Error Condition/Major Cause/Solution
SC685-01D24VS Power Supply Voltage Error
  Tracks for 2.5 second (timeout) from the time the +24VS1 converter ON/OFF turns ON (SWTRG1_PO=0 to 1).
  • PSU malfunctioning
  • IOB malfunctioning
  • Connecter disconnected
  • Harness broken or ground fault
  • Load fault
  1. Check whether the power supply LED (LED4) on the IOB is lit to orange.
    • LED4 is lit: execute step 2.
    • LED4 is not lit: execute step 2 and then step 3.
  2. Check and replace the harnesses of the IOB and PSU1 if they are broken or have defective grounding. Then, turn the machine OFF/ON to check the SC occurrence.
    • The SC occurred: execute step 4 (or 3).
  3. Reconnect the cables of the IOB and PSU1. Then, turn the machine OFF/ON to check the SC occurrence.
    • The SC occurred: execute step 5.
  4. Replace the IOB. Then, turn the machine OFF/ON to check the SC occurrence.
    • The SC occurred: execute step 5.
  5. Replace the PSU1. Then, turn the machine OFF/ON to check the SC occurrence.
SC No.LevelError Name/Error Condition/Major Cause/Solution
SC685-02BADF 24V Power Supply Voltage Error






Tracks for 2.5 second (timeout) from the time the machine turns ON or returns from energy save mode.
  • PSU malfunctioning
  • Connecter disconnected
  • Harness broken or ground fault
  1. Check whether the power supply LED (LED3) on the IOB is lit to yellow.
    • LED3 is lit: no treatment is necessary.
    • LED3 is not lit: execute step 2.
  2. Check and replace the harness of the PSU2 if it is broken or has defective grounding. Then, turn the machine OFF/ON to check the SC occurrence.

    • The SC occurred: execute step 3.
  3. Replace the PSU2. Then, turn the machine OFF/ON to check the SC occurrence.
SC No.LevelError Name/Error Condition/Major Cause/Solution
SC685-03BDUB 24VS Power Supply Voltage Error
  Tracks for 1 second (timeout) from the time the cleaning web motor is turned ON on the software.
  • PSU malfunctioning
  • Connecter disconnected
  • Harness broken or ground fault
  • Cleaning web motor malfunctioning
  • DUB malfunctioning
  1. Check whether the power supply LED (LED5) on the DUB is lit to orange.
    • LED5 is lit: execute step 2.
    • LED5 is not lit: execute step 2 and then step 3.
  2. Check and replace the harnesses of the DUB and PSU1 if they are broken or have defective grounding. Then, turn the machine OFF/ON to check the SC occurrence.
    • The SC occurred: execute step 4 (or 3).
  3. Reconnect the cables of the DUB and PSU1. Then, turn the machine OFF/ON to check the SC occurrence.
    • The SC occurred: execute step 5.
  4. Replace the DUB. Then, turn the machine OFF/ON to check the SC occurrence.
    • The SC occurred: execute step 5.
  5. Replace the PSU1. Then, turn the machine OFF/ON to check the SC occurrence.
    • The SC did not occur: check the cleaning web motor with the OUTPUT command in SP mode.
SC No.LevelError Name/Error Condition/Major Cause/Solution
SC685-04BIOB 24V Power Supply Voltage Error
  Tracks for 2.5 second (timeout) from the time the skew correction motor Y/M/C/K are turned ON on the software.
  • PSU malfunctioning
  • Connecter disconnected
  • Harness broken or ground fault
  • Cleaning motor malfunctioning
  • Image skew correction motor (Y/M/C/K) malfunctioning
  1. Check whether the power supply LED (LED3) on the IOB is lit to yellow.
    • LED3 is lit: execute step 2.
    • LED3 is not lit: execute step 2 and then step 3.
  2. Check and replace the harnesses of the IOB and PSU1 if they are broken or have defective grounding. Then, turn the machine OFF/ON to check the SC occurrence.
    • The SC occurred: execute step 4 (or 3).
  3. Reconnect the cables of the IOB and PSU1. Then, turn the machine OFF/ON to check the SC occurrence.
    • The SC occurred: execute step 5.
  4. Replace the IOB. Then, turn the machine OFF/ON to check the SC occurrence.
    • The SC occurred: execute step 5.
  5. Replace the PSU2. Then, turn the machine OFF/ON to check the SC occurrence.
    • The SC did not occur: check the image correction motor with the OUTPUT command in SP mode.
SC No.LevelError Name/Error Condition/Major Cause/Solution
SC685-05BPFB 24V Power Supply Voltage Error 1
  Tracks for 2.5 second (timeout) from the time the HAISHI_FAN_O is turns ON on the software.
  
  • PSU malfunctioning
  • Connecter disconnected
  • Harness broken or ground fault
  • Fans for Booklet Finisher SR4130/Finisher SR4120 (Cooling Fan Unit Type M26) malfunctioning
  • PFB malfunctioning
  
  1. Check whether the power supply LED (LED4) on the PFB is lit to yellow.
    • LED4 is lit: execute step 2.
    • LED4 is not lit: execute step 2 and then step 3.
  2. Check and replace the harnesses of the PFB and PSU1 if they are broken or have defective grounding. Then, turn the machine OFF/ON to check the SC occurrence.
    • The SC occurred: execute step 4 (or 3).
  3. Reconnect the cables of the PFB and PSU2. Then, turn the machine OFF/ON to check the SC occurrence.
    • The SC occurred: execute step 5.
  4. Replace the PFB. Then, turn the machine OFF/ON to check the SC occurrence.
    • The SC occurred: execute step 5.
  5. Replace the PSU2. Then, turn the machine OFF/ON to check the SC occurrence.
    • The SC did not occur: check the fan for Booklet Finisher SR4130/Finisher SR4120 (Cooling Fan Unit Type M26) with the OUTPUT command in SP mode.
SC No.LevelError Name/Error Condition/Major Cause/Solution
SC685-06BPFB 24V Power Supply Voltage Error 2
  Tracks for 2.5 second (timeout) from the time the CLTLKSL_DRV_O is turns ON on the software.
  
  • PSU malfunctioning
  • Connecter disconnected
  • Harness broken or ground fault
  • Left tray lock solenoid malfunctioning
  • PFB malfunctioning
  
  1. Check whether the power supply LED (LED4) on the PFB is lit to yellow.
    • LED4 is lit: execute step 2.
    • LED4 is not lit: execute step 2 and then step 3.
  2. Check and replace the harnesses of the PFB and PSU1 if they are broken or have defective grounding. Then, turn the machine OFF/ON to check the SC occurrence.
    • The SC occurred: execute step 4 (or 3).
  3. Reconnect the cables of the PFB and PSU2. Then, turn the machine OFF/ON to check the SC occurrence.
    • The SC occurred: execute step 5.
  4. Replace the PFB. Then, turn the machine OFF/ON to check the SC occurrence.
    • The SC occurred: execute step 5.
  5. Replace the PSU2. Then, turn the machine OFF/ON to check the SC occurrence.
    • The SC did not occur: check the solenoid with the OUTPUT command in SP mode.