Each peripheral unit for this machine has the same single-piece connection bracket shown below. This adjustment can be done for every unit on the connection bracket attached to the upstream device
- Enter the SP mode and set SP1-206-001 to "2" (OFF).
 - Disconnect the peripheral unit from the upstream device.
 - On the connecting bracket attached to the upstream device, loosen screw 
,
,
, and
.
 - Remove bracket [A] (
x1), rotate it 90 degrees, and re-fasten the screw. Changing the position of this bracket aligns the oval cut-out horizontally and frees the connecting bracket so it can slide from side to side.
 - Look at the scale [B].
 - Slide the bracket to the left or right and tighten the screw.
 - If the deviation from center was toward the front, slide the bracket to the rear and tighten screw 
.
-or-
If the deviation from center was toward the rear, side the bracket to the front and tighten screw.
 - Tighten screws 
,
, and
.
 - Do another test run, so that you can check the results of the adjustment.
 - When you are finished, enter the SP mode and re-set SP1-206-001 to "1".