1. If the upstream device is the main machine, prepare the guide sheet [A] provided with the main machine.
    If the upstream device is not the main machine, proceed to step 5.
  2. Divide the entrance guide plate [A] into two parts.
  3. Remove the release paper from the guide sheet [A], and attach the guide sheet to the side of the upper entrance guide plate [B] which will become the inner side when assembled.

    [C]: Position the edge of the guide sheet 5 mm inside from the edge of the upper entrance guide plate.
    [D]: Align the edge of the adhesive tape with the edge of the upper entrance guide plate.
  4. Reassemble the entrance guide plate [A].
  5. Install the entrance guide plate [A] on the right side of the finisher.
  6. Do not attach the right upper cover if you are going to install Cover Interposer Tray CI4020 (D712).
    -or-
    Set the tabs of the right upper cover [A] at the right rear corner of the finisher, and then attach the cover at the front [B].
  7. Hook the grounding plate [A] onto the right bottom edge of the finisher, and then attach it [B] with the screws.
  8. Peel the tape from the large sponge strip.
  9. Attach the strip to the right top edge of the finisher so that it is 0 to 1 mm from the top edge.