Update judgement is done when the latest update package is successfully downloaded, or the package has already been downloaded.
If the judgement timing is in the range of the update prohibited time or day set with SP or WIM, the machine will retry the update after 76 hours.
If the machine is in use when the judgement process runs, the process is retried. Retry is done up to three times every hour (can be changed with SP) and if the machine is in use for all three retries, the machine will retry the update after 76 hours
Situations judged as machine in use
No. | Situations judged as machine in use |
---|---|
1 | When the control panel is used within 30 seconds |
2 | During firmware update |
3 | While firmware update is disabled |
4 | While printing (re-printing via network) |
5 | Retrieving image data via network |
6 | While initial setting (User Tools settings) or SP is being set |
7 | While shifting to/from the energy server mode |
8 | When not being able to run firmware update due to the modules that are running e.g.) Waiting for DCS transfer (refer to appendix), accessing devices such as HDD/SD card, etc. |
9 | While displaying a preview |
10 | While displaying the printer menu |
11 | While writing log information |
12 | While accessing the address book |
13 | During SC |