- Referring to the previous procedure, be sure that there are no mistakes in the mounting position and orientation of the NVRAM.
- If you mounted the NVRAM in the wrong direction, each component needs to be replaced because a short circuit was caused in the controller board and the NVRAM.
- Make sure you have the SMC report (factory settings). This report comes with the machine.
- Output all the SMC data using SP5-990-001 (SP Print Mode: All (Data List)).
- Turn off the main power switch.
- Insert a blank SD card in SD slot 2, and then turn on the main power switch.
- Use SP5-824-001 to upload the NVRAM data from the controller board.
- Make sure the customer has a backup of their address book data. If not, obtain the backup by referring to the following procedure.
- Insert an SD card into SD slot 2, and then turn the main power ON.
- Save the address book data in the SD card using SP5-846-051.
- The address data stored in the machine will be discarded later during this procedure. So be sure to obtain a backup of the customer’s address book data.
- Note that the counters for the user will be reset when doing the backup/restore of the address book data.
- If they have a backup of the address book data, use their own backup data for restoring. This is because there is a risk that the data cannot be backed up properly depending on the NVRAM condition.
- Turn the main power OFF and unplug the power supply cord.
- Push the main power switch ON again to discharge the residual charge.
- Remove the SD card from SD slot 2.
- Replace the NV-RAM with a brand-new one.
Turn the power ON while the SD card is removed from SD slot 2.
- SC673 appears at start-up, but this is normal behavior. This is because the controller and the smart operation panel cannot communicate with each other due to changing the SP settings for the operation panel.
- Change the SP settings for the operation panel.
If you switch the screen to enter the SP mode, SC995-02 is displayed. However, continue the following steps.SP5-748-101: (OpePanel Setting: Op Type Action Setting): Change bit 0 from 0 to 1.
SP5-748-201: (OpePanel Setting: Cheetah Panel Connect Setting): Change the value from 0 to 1.
Cycle the power OFF/ON.
- The model information is written on the NVRAM (Novita), so SC995-02 does not occur.
- Program/Change Administrator will be displayed in Japanese, but this is normal.
Turn OFF the main power, take the SD card to which the NV-RAM data has been uploaded, and insert it into SD slot 2.
- Turn ON the main power.
Download the NV-RAM data stored in the SD card to the brand-new NV-RAM using SP5-825-001 (NV-RAM Data Download).
- The download will take a couple of minutes.
- Turn the power OFF and remove the SD card from slot 2.
Turn the power ON.
The screen "Program/Change Administrator" will be displayed in the language that is the same language as the time when the data was uploaded to the SD card in step 5.- If the security functions (e.g. Stored file encryption/ Auto Erase Memory Setting) were applied, set the functions again.
Ask the customer to restore their address book. Or restore the address book data using SP5-846-052 (UCS Setting: Restore All Addr Book), and ask the customer to ensure the address book data has been restored properly.
- If you obtained the backup of the customer’s address book data in step 3, delete the backup immediately after the NV-RAM replacement to avoid accidentally taking out the customer’s data.
Output all the SMC data with SP5-990-001 and make sure all the SP/UP settings except for counter information are properly restored, by checking the SMC data obtained in step 2.
- The counters will be reset.
If the setting is different from the original setting after the replacement of the NVRAM, then set it again to the original setting.
- Execute the process control (SP3-011-001).
Cycle the power OFF/ON.
- If you cannot execute SP5-824-001 or SP5-825-001 for some reason, try all the following things.
- Check the changed SP value on the SMC which was output in step 2 and set it manually. Especially, ensure that the values of the following SPs are same as the setting before the replacement.
- a. SP5-104-001 (A3/DLT Double Count)
- b. SP5-104-002 (Bypass Paper Size Undetection)
- c. SP5-302-002 (Set Time: Time Difference) - Because the PM counters have been reset during NV-RAM replacement, it is necessary to replace all the PM parts for proper PM management.
- If a message tells you need a SD card to restore displays after the NV-RAM replacement, create a “SD card for restoration” and restore with the SD card.
- If you cannot execute SP5-824-001 or SP5-825-001 for some reason, try all the following things.