SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC816 | [0x0000] | Energy save I/O subsystem error |
SC816-01 | D | Subsystem error |
SC816-02 | D | Sysarch (LPUX_GET_PORT_INFO) error |
SC816-03 | D | Transition to STR was denied. |
SC816-04 | D | Interrupt in kernel communication driver |
SC816-05 | D | Preparation for transition to STR failed. |
SC816-07 | D | Sysarch (LPUX_GET_PORT_INFO) error |
SC816-08 | D | Sysarch (LPUX_ENGINE_TIMERCTRL) error |
SC816-09 | D | Sysarch (LPUX_RETURN_FACTOR_STR) error |
SC816-10 to 12 | D | Sysarch (LPUX_GET_PORT_INFO) error |
SC816-13 | D | open() error |
SC816-14 | D | Memory address error |
SC816-15 to 18 | D | open() error |
SC816-19 | D | Double open() error |
SC816-20 | D | open() error |
SC816-22 | D | Parameter error |
SC816-23, 24 | D | read() error |
SC816-25 | D | write () error |
SC816-26 to 28 | D | write() communication retry error |
SC816-29, 30 | D | read() communication retry error |
SC816-35 | D | read() error |
SC816-36 to 99 | D | Subsystem error |
Energy save I/O subsystem detected some abnormality. | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC840-00 | D | EEPROM access error |
| ||
| ||
- |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC841-00 | D | EEPROM read data error |
Mirrored data of the EEPROM is different from the original data in EEPROM. | ||
Data in the EEPROM is overwritten for some reason. | ||
- |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC842-00 | C | Nand-Flash updating verification error |
SCS write error (verify error) occurred at the Nand-Flash module when remote ROM or main ROM was updated. | ||
Nand-Flash defective | ||
Turn the main power OFF/ON. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC842-01 | B | Insufficient Nand-Flash blocks (threshold exceeded) |
At startup, or when machine returned from low power mode, the Nand-Flash status was read and judged that the number of unusable blocks had exceeded threshold, and then SCS generated the SC code. | ||
Number of unusable blocks exceeded threshold for Nand-Flash | ||
Replace the controller board. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC842-02 | B | Number of Nand-Flash block deletions exceeded |
At startup, or when the machined returned from low power mode, the Nand-Flash was read and judged that the number of deleted blocks had exceeded threshold, and then SCS generated this SC code. | ||
Number of blocks deleted exceeded threshold for Nand-Flash | ||
Replace the controller board. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC845 | Hardware Error Detected when the automatic firmware update | |
SC845-01 | D | Engine Board |
SC845-02 | D | Controller Board |
SC845-03 | D | Operation Panel (Normal) |
SC845-04 | D | Operation Panel (Smart Panel) |
SC845-05 | D | FCU |
When updating the firmware automatically (ARFU), the firmware cannot be read or written normally, and the firmware update cannot be completed even by 3 retries. | ||
Hardware abnormality of the target board | ||
Replace the target board. For SC845-02, HDD and memory may cause the problem. Replace the HDD or memory if the SC cannot be recovered by replacing the controller board. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC860-00 | B | HDD startup error at main power on (HDD error) |
| ||
| ||
Format the HDD through SP mode. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC865-00 | D | HD access error |
During HDD operation, the HDD returned an error. | ||
The HDD returned an error that does not constitute SC863 (bad sector) or SC864 (CRC error). | ||
Replace the HDD. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC866-00 | B | SD card authentication error |
A license error of an application that is started from the SD card was detected. | ||
Invalid program data is stored on the SD card. | ||
Store a valid program data on the SD card. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC867-00 | C | SD card removed |
The SD card was removed while the machine is on. | ||
An application SD card has been removed from the slot (mount point of /mnt/sd0). | ||
Turn the main power off/on. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC867-01 | C | SD card removed |
The SD card was removed while the machine is on. | ||
An application SD card has been removed from the slot (mount point of /mnt/sd1). | ||
Turn the main power off/on. |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC867-02 | C | SD card removed |
The SD card was removed while the machine is on. | ||
An application SD card has been removed from the slot (mount point of /mnt/sd2). | ||
Turn the main power OFF/ON. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC868-00 | D | SD card access error |
The SD controller returned an error during operation. (An error occurred at the mount point of /mnt/sd0) | ||
| ||
|
* Do not format an SD card supplied with the main machine or sold as an option. You may only format SD cards used for Firmware Update by a Customer Engineer.
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC868-01 | D | SD card access error |
The SD controller returned an error during operation. (An error occurred at the mount point of /mnt/sd1) | ||
| ||
SD card that starts an application
|
* Do not format an SD card supplied with the main machine or sold as an option. You may only format SD cards used for Firmware Update by a Customer Engineer.
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC868-02 | D | SD card access error |
The SD controller returned an error during operation. (An error occurred at the mount point of /mnt/sd1) | ||
| ||
SD card that starts an application
|
* Do not format an SD card supplied with the main machine or sold as an option. You may only format SD cards used for Firmware Update by a Customer Engineer.
No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC869-** | Malfunction of the proximity sensor is detected | |
SC869-01 | C | Continuously detecting malfunction |
The proximity sensor keeps in a detection state and accumulated time exceeds 24 hours. | ||
The proximity sensor is disabled and is in the detection state at all times. | ||
SC869-02 | C | Continuously non-detecting malfunction |
In the non-detection state, the following operations are detected 20 times continuously.
| ||
The proximity sensor is disabled and is in the non-detection state at all times. | ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC870-00 | B | Address Book data error (Anytime: Address Book Error.) |
SC870-01 | B | Address Book data error (On startup: Media required for storing the Address Book is missing.) |
SC870-02 | B | Address Book data error (On startup: encryption is configured but the module required for encryption (DESS) is missing.) |
SC870-03 | B | Address Book data error (Initialization: Failed to generate a file to store internal Address Book.) |
SC870-04 | B | Address Book data error (Initialization: Failed to generate a file to store delivery sender.) |
SC870-05 | B | Address Book data error (Initialization: Failed to generate a file to store delivery destination.) |
SC870-06 | B | Address Book data error (Initialization: Failed to generate a file to store information required for LDAP search.) |
SC870-07 | B | Address Book data error (Initialization: Failed to initialize entries required for machine operation.) |
SC870-08 | B | Address Book data error (Machine configuration: HDD is present but the space for storing the Address Book is unusable.) |
SC870-09 | B | Address Book data error (Machine configuration: Inconsistency in the NVRAM area used for storing settings required for Address Book configuration.) |
SC870-10 | B | Address Book data error (Machine configuration: Cannot make a directory for storing the Address Book in the SD/USB FlashROM.) |
SC870-11 | B | Address Book data error(On startup: Inconsistency in Address Book entry number.) |
SC870-20 | B | Address Book data error (File I/O: Failed to initialize file.) |
SC870-21 | B | Address Book data error (File I/O: Failed to generate file.) |
SC870-22 | B | Address Book data error (File I/O: Failed to open file.) |
SC870-23 | B | Address Book data error (File I/O: Failed to write to file.) |
SC870-24 | B | Address Book data error (File I/O: Failed to read file.) |
SC870-25 | B | Address Book data error (File I/O: Failed to check file size.) |
SC870-26 | B | Address Book data error (File I/O: Failed to delete data.) |
SC870-27 | B | Address Book data error (File I/O: Failed to add data.) |
SC870-30 | B | Address Book data error (Search: Failed to obtain data from cache when searching in the machine Address Book. delivery destination/sender.) |
SC870-31 | B | Address Book data error (Search:Failed to obtain data from cache during LDAP search.) |
SC870-32 | B | Address Book data error (Search:Failed to obtain data from cache while searching the WS-Scanner Address Book.) |
SC870-41 | B | Address Book data error (Cache: failed to obtain data from cache.) |
SC870-50 | B | Address Book data error (On startup: Detected abnormality of the Address Book encryption status.) |
SC870-51 | B | Address Book data error (Encryption settings: Failed to create directory required for conversion between plaintext and encrypted text.) |
SC870-52 | B | Address Book data error (Encryption settings: Failed to convert from plaintext to encrypted text.) |
SC870-53 | B | Address Book data error (Encryption settings: Failed to convert from encrypted text to plaintext.) |
SC870-54 | B | Address Book data error (Encryption settings: Detected data inconsistency when reading the encrypted Address Book.) |
SC870-55 | B | Address Book data error (Encryption settings: Failed to delete file when changing encryption setting.) |
SC870-56 | B | Address Book data error (Encryption settings: Failed to erase the file that records the encryption key during an attempt to change the encryption setting.) |
SC870-57 | B | Address Book data error (Encryption settings: Failed to move a file during an attempt to change the encryption setting.) |
SC870-58 | B | Address Book data error (Encryption settings: Failed to delete a directory during an attempt to change the encryption setting.) |
SC870-59 | B | Address Book data error (Encryption settings: Detected a resource shortage during an attempt to change the encryption setting.) |
SC870-60 | B | Address Book data error (Unable to obtain the on/off setting for administrator authentication (06A and later).) |
When an error related to the Address Book is detected during startup or operation. | ||
| ||
Install a device that contains address book information correctly, and turn the main power off/on. If the SC occurs again, do the following steps.
Procedure after SC870 is cleared
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC872-00 | B | HDD mail reception error |
An error was detected on the HDD immediately after the machine was turned on. | ||
| ||
When you do the above, the following information will be initialized.
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC873-00 | B | HDD mail reception error |
An error was detected on the HDD immediately after the machine was turned on. | ||
| ||
When you do the above, the following information will be initialized.
|
No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC874-05 | D | Delete all error (Delete data area) : Read error |
SC874-06 | D | Delete all error (Delete data area) : Write error |
SC874-09 | D | Delete all error (Delete data area) : No response from HDD |
SC874-10 | D | Delete all error (Delete data area) : Error in Kernel |
SC874-12 | D | Delete all error (Delete data area) : No designated partition |
SC874-13 | D | Delete all error (Delete data area) : No device file |
SC874-14 | D | Delete all error (Delete data area) : Start option error |
SC874-15 | D | Delete all error (Delete data area) : No designated sector number |
SC874-16 | D | Delete all error (Delete data area) : failure in performing hdderase |
SC874-41 | D | Delete all error (Delete data area) : Other fatal errors |
SC874-42 | D | Delete all error (Delete data area) : End by cancellation |
SC874-61 to -65 | D | Delete all error (Delete data area) : library error |
SC874-66 | D | Delete all error (Delete data area) : Unavailable |
SC874-67 | D | Delete all error (Delete data area) : Erasing not finished |
SC874-68 | D | Delete all error (Delete data area) : HDD format failure (Normal) |
SC874-69 | D | Delete all error (Delete data area) : HDD format failure (Abnormal) |
SC874-70 | D | Delete all error (Delete data area) : Unauthorized library |
SC874-99 | D | Delete all error (Delete data area) : other errors |
An error occurred while data was being erased on HDD or NVRAM. | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC875-01 | D | Delete all error (HDD erasure) (hddchack –i error) |
SC875-02 | D | Delete all error (HDD erasure) (Data deletion failure) |
An error was detected before HDD/data erasure starts. (Failed to erase data/failed to logically format HDD) | ||
| ||
Turn the main power off/on. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC876-00 | D | Log Data Error |
An error was detected in the handling of the log data at power on or during machine operation. | ||
| ||
Try the SC876-01 to -99 solutions listed below. If it is not solved, do the following steps (for when only an HDD is replaced):
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC876-01 | D | Log Data Error 1 |
An error was detected in the handling of the log data at power on or during machine operation. | ||
Damaged log data file | ||
Initialize the HDD (SP5-832-004). |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC876-02 | D | Log Data Error 2 |
An error was detected in the handling of the log data at power on or during machine operation. | ||
Log encryption is enabled but encryption module is not installed. | ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC876-03 | D | Log Data Error 3 |
An error was detected in the handling of the log data at power on or during machine operation. | ||
Inconsistency of encryption key between NV-RAM and HDD. | ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC876-04 | D | Log Data Error 4 |
An error was detected in the handling of the log data at power on or during machine operation. | ||
| ||
Initialize the HDD (SP5-832-004). |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC876-05 | D | Log Data Error 5 |
An error was detected in the handling of the log data at power on or during machine operation. | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC876-99 | D | Log Data Error 99 |
An error was detected in the handling of the log data at power on or during machine operation. | ||
Other causes | ||
- |
No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC877-00 | B | Data Overwrite Security card error |
The "Auto Erase Memory" function of the Data Overwrite Security is set to on but it cannot be done. | ||
| ||
|