With this feature, you can save debug logs that are stored in the machine (HDD or operation panel) on an SD card. It allows the Customer Engineer to save and retrieve error information for analysis.
The Capturing Log feature saves debug logs for the following four.
- Controller debug log including operation log
- Engine debug log
- FCU debug log
- Operation panel log
- In older models, a technician enabled the logging tool after a problem occurred. After that, when the problem had been reproduced, the technician was able to retrieve the debug log.
- However, this new feature saves the debug logs at the time that problems occur. Then you can copy the logs to an SD card.
- You can retrieve the debug logs using a SD card without a network.
- Analysis of the debug log is effective for problems caused by the software. Analysis of the debug log is not valid for the selection of defective parts or problems caused by hardware.
Types of debug logs that can be saved
Type | Storage Timing | Destination (maximum storage capacity) |
---|---|---|
Controller debug log including operation log |
| HDD (4 GB) or SD card connected to the service slot. When the data gets over 4.0 GB, the older data is deleted. |
Engine debug log |
| HDD or SD card connected to the service slot (Up to 300 times) |
FCU debug log |
| HDD or SD card connected to the service slot |
Operation panel log |
| Memory in the operation panel. |
- Debug logs are not saved in the following conditions:
- While erasing all memory
- While data encryption equipment is installed
- While changing the firmware configuration
- Forced power OFF (accidentally disconnecting the outlet)
- Engine debug log in shutdown
- When the power supply to the HDD is off because of energy saving (engine OFF mode /STR mode)
- When one of the following SC occurs: SC672, SC816, SC819, SC878, SC899, SC859, SC860, SC861, SC863, or SC864
- Following logs are not saved:
- Log related to the energy saver mode (Engine-off, suspend-mode, or other cases)
Network communication log
Logs related to NRS
IP-FAX log
Access log for unauthorized user (guest) - HTTP session timeout log
- Auto log-out log
- IC card related log
- Authorization for Fax