Level

Definition

Reset Procedure

A

To prevent damage to the machine, the main machine cannot be operated until the SC has been reset by a service representative (see the note below).

Enter SP mode, go into SP5-810-001, press [Execute], and turn the main power switch off and on.

B

SCs that disable only the features that use the defective item. Although these SCs are not shown to the user under normal conditions, they are displayed on the operation panel only when the defective feature is selected.

Turn the main power switch off and on.

C

The SC history is updated. The machine can be operated as usual.

The SC will not be displayed. Only the SC history is updated.

D

Turning the main power switch off then on resets SCs displayed on the operation panel. These are re-displayed if the error occurs again.

Turn the main power switch off and on.