1. Confirm that the Data Overwrite Security unit SD card is the correct type for this machine. The correct type is Type M19.

    • If you install any type other than Type M19, you will have to replace the NVRAM and perform this installation procedure again.

  2. Make sure that the following settings are not at their factory defaults:
    • Supervisor login password
    • Administrator login name
    • Administrator login password
    If any of these settings is at a factory default, ask the customer to change the settings before you perform the installation procedure.
  3. Make sure that "Admin. Authentication" is ON.
    User Tools > Machine Features > System Settings > Administrator Tools > Administrator Authentication Management > Admin. Authentication
    If this setting is OFF, ask the customer to change the setting to ON before you perform the installation procedure.
  4. Make sure that "Administrator Tools" is enabled (selected).
    User Tools > Machine Features > System Settings > Administrator Tools >
    Administrator Authentication Management> Available Settings
    If this setting is disabled (not selected), ask the customer to enable (select) the setting before you perform the installation procedure.

  • See the Operating Instructions (Security Guide) for the factory defaults.