SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC302

D

High voltage output error: Charge unit /Development unit

This SC is issued if the BiCU detects a short in the power pack 10 times consecutively.

Short circuit (-)

  • Replace the controller board.
  • Check the connector connection.

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC332-00

D

Toner supply feed lock

Under the condition that the Toner Cartridge has not reached the end, an error that no toner is supplied has been detected over n times in succession.

n: The value was specified at SP2-931-005.

  • Overloaded toner feeding system (toner clogging)

  • Detection screw of the PCDU not rotating

  • Failure in the sensing element (sensor): Light leak

  • Failure in the toner supply pawl

  • Failure in the toner supply clutch

  • Replace the Toner Cartridge.
  • Replace the PCDU

SC No.

Level

Error Name/Error Condition/Major Cause/Solution

SC364-00

D

Toner End Sensor output count error

Under the condition that the toner cartridge has not reached the end, an error that no toner is supplied has been detected over n times in succession. (where n is to be configured using SP2-931-003)

  • Bad connector contact or connector disconnected/wire broken
  • Failed toner end sensor
  • Dirty detection surface inside the development unit
  • Check the connector connection or check for broken wire.
  • Replace the harness.
  • Replace the toner end sensor.
  • Replace the PCDU.