Before the scanner adjustment, do the Side-to-Side registration and blank margin width adjustment.
- Use a test chart to adjust these settings.
Magnification
A: Sub-scan magnification
- Place the test chart on the exposure glass and make a copy from one of the paper feed trays.
Check the magnification ratio. If necessary, adjust the magnification with the following SP mode.
SP No.
Name
Specification
SP4-008
Sub-scan magnification
± 1.0%
Registration
- A: Leading edge registration
- B: Side-to-side registration
- Place the test chart on the exposure glass and make a copy from one of the paper feed trays.
Check the leading edge and side-to-side registration, and adjust as necessary with the following SP modes.
Name
SP No.
Specification
L-Edge Regist Adjustment
SP4-010-001
0 ± 2mm
S-to-S Regist Adjustment
SP4-011-001
0 ± 2.5mm