Modem Settings | RX Level | Sets the reception level. [-43 dBm (Default)/ -33 dBm/ -26 dBm/ -16 dBm] |
TX Level | Sets the transmission level. [-15 to -1 / -9(Default)/ 1dBm/ step] | |
Cable Equalizer | These selectors are used to improve the pass-band characteristics of analogue signals on the telephone line. [0Km (Default)/ 1.8Km/ 3.6Km/ 7.2Km] | |
Protocol Definition | Training Retries | This sets the number of training retries to be repeated before automatic fallback. [1 Time/ 2 Times (Default)/ 3 Times/ 4 Times] |
Encoding | Sets the compression method for Tx/Rx. [MMR+MR+MH (Default)/ MR+MH/ MH] | |
Protocol Definition Timer | T0 Timer | Timeout for response from the called station in automatic sending mode [35 Sec/ 45 Sec/ 55 Sec (Default)/ 60 Sec/ 90 Sec/ 140 Sec] |
T1 Timer | Set the time length for the T1 timer. [40 Sec (Default)/ 50 Sec] | |
T4 Timer | Set the time length for the T4 timer. [3 Sec (Default/ 4.5 Sec] | |
RX Settings | CNG Tone Detection | CNG tone detection time (RX mode : FAX / TEL, FAX / TAD Only) After the line is connected via the external telephone, the machine can detect a CNG signal for the time length specified by this setting. [5 Sec (Default)/ 10 Sec] |
CNG Cycles | Number of CNG cycles to be detected This setting is only effective for FAX/TAD mode. [1.5 Cycle (Default)/ 2.0 Cycle] | |
Tone Sound Monitoring | Determines the period when tones from the line are monitored. [No Monitoring/ Up To Phase B (Default)/ All TX Phases] | |
Stop/Clear Key | Pressing the Stop/Clear key can stop the current receiving operation. Received data is lost. [No Functional (Default)/ Functional] | |
Off-Hook Detection | Sets the Off-Hook detection period. [200 msec (Default)/ 800 msec] | |
Number for Remote Switch | [0~9 / 2 (Default/ 1digit/step] | |
Number of time to press | [1~3 / 2 (Default/ 1time/step] | |
Period: TEL to Fax | [Limitless / 10 sec (Default/ 20 sec / 30 sec / 40 sec] | |
TX Settings | Redial Interval | Sets the redial interval when Tx fails. [5 Min (Default)/ 6 Min] |
Redialings | Sets the number of redials when Tx fails. [2 times (Default)/ 3 Times/ 4 Times/ 5 Times] | |
Overseas Comm Mode Settings | Overseas Comm Mode | This sets the machine to ignore a DIS signal sent from the called station once in a sending operation. [Off (Default)/ Ignore DIS Once] |
Minimum Time Length | If this setting is set to "On", the machine detects the CNG signal after the line is connected. If it is set to "Off", the machine detects the CNG signal as long as the line is connected. [100 Ms/ 200 Ms/ 300 Ms/ 400 Ms (Default)] | |
Dial Pulse Setting | Dial Pulse Type | This sets the number of pulses that are generated during dialing.
|
Tone Signal Settings | Tone Signal Transmission T | Sets the tone signal transmission time length [100 ms (Default)] |
Minimum Pause In Tone Dial | Sets the minimum pause during tone dialing [100 ms (Default)/ 150 ms/ 200 ms] | |
Attenuator of Pseudo Ring | Sets the attenuator for pseudo ringback tone to the line [0 to 15 / 10 (Default)/ 1 dB/step] | |
DTMF Level | Sets the transmission level of DTMF tones. [-12 dBu / -11 dBu/ -10 dBu (Default)/ -8 dBu/ -6 dBu] | |
DTMF Delta | Sets the level difference between high band frequency signals and low band frequency signals when sending DTMF tones. [1 dBu/ 2 dBu (Default)/ 3 dBu] | |
1Dial Tone Detection | Wait Time | The machine starts dialing after the specified interval without detection of a dial tone when dial tone detection is set to "No detection". [3.5 Sec (Default)/ 7.0 Sec/ 10.5 Sec/ 14.0 Sec] |
Timeout Length | This setting sets the time-out length for the 1st dial tone detection. The machine waits for a dial tone for the specified time and disconnects itself from the line when no dial tone is input. [10 Sec (Default)/ 15 Sec/ 20 Sec/ 30 Sec] | |
BT (Busy Tone) Detection | BT Setting | DFU [Off/ On(Default)] |
BT Frequency | DFU [300-550 Hz/ 300-650 Hz/ 325-525 Hz/ 340-550 Hz/ 350-500 Hz (Default)/ 350-550 Hz/ 375-475 Hz/ 380-520 Hz] | |
BT Level | DFU [-35 dB/ -36 dB/ -37 dB/ -38 dB/ -39 dB (Default)] | |
BT Cadence | DFU [0.10/ 0.15/ 0.20/ 0.25/ 0.30/ 0.35/ 0.40/ 0.45/ 0.50 (Default)/ 0.75] | |
Comm Settings | RTN Rate | The machine checks the actual data reconstruction errors and then transmits an RTN depending on the decoding error rate that is set by this setting (Number of lines containing an error per page / Total number of lines per page). [10% (Default)/ 15%] |
V34 Modem | DFU [Permitted (Default)/ Prohibited] | |
V17 Modem | DFU [Permitted (Default)/ Prohibited] | |
V34 Settings | Equalizer | DFU These selectors set the equalizer's training level to be applied if training fails due to poor line connection. [Automatic (Default)/ 4 Points/ 16 Points] |
Redialing | Resend when a communication error occurs. [Disabled (Default)/ Not Disabled] | |
First TX Speed | Sets the first transmission speed choice, before fallback. [2400 Bps/ 4800 Bps/ 7200 Bps/ 9600 Bps/ 12000 Bps/ 14400 Bps/ 16800 Bps/ 19200 Bps/ 21600 Bps/ 24000 Bps/ 26400 Bps/ 28800 Bps/ 31200 Bps/ 33600 Bps (Default)] | |
Symbol Rate | This setting limits the transmission speed range in V.34 mode by masking the desired symbol rate(s). [Not Used (Default)/ 3429 Sym/Sec/ 3200 Sym/Sec/ 3000 Sym/Sec/ 2800 Sym/Sec/ 2400 Sym/Sec] | |
All Document Transfer | Transfers all documents in fax memory to another fax machine. Emergency use only. Input the forwarding fax number. Max. 40 digits (includes #, *) To start transferring all documents, press the “Start” key. To cancel all documents from transferring and go back to the Fax Maintenance menu, press the “Clear/Stop” key. |