MenuDescription
Modem Settings

RX Level

Sets the reception level.

[-43 dBm (Default)/ -33 dBm/ -26 dBm/ -16 dBm]

TX Level

Sets the transmission level.

[-15 to -1 / -9(Default)/ 1dBm/ step]

Cable Equalizer

These selectors are used to improve the pass-band characteristics of analogue signals on the telephone line.

[0Km (Default)/ 1.8Km/ 3.6Km/ 7.2Km]

Protocol DefinitionTraining Retries

This sets the number of training retries to be repeated before automatic fallback.

[1 Time/ 2 Times (Default)/ 3 Times/ 4 Times]

Encoding

Sets the compression method for Tx/Rx.

[MMR+MR+MH (Default)/ MR+MH/ MH]

Protocol Definition Timer

T0 Timer

Timeout for response from the called station in automatic sending mode

[35 Sec/ 45 Sec/ 55 Sec (Default)/ 60 Sec/ 90 Sec/ 140 Sec]

T1 Timer

Set the time length for the T1 timer.

[40 Sec (Default)/ 50 Sec]

T4 Timer

Set the time length for the T4 timer.

[3 Sec (Default/ 4.5 Sec]

RX Settings




CNG Tone Detection

CNG tone detection time (RX mode : FAX / TEL, FAX / TAD Only)

After the line is connected via the external telephone, the machine can detect a CNG signal for the time length specified by this setting.

[5 Sec (Default)/ 10 Sec]

CNG Cycles

Number of CNG cycles to be detected

This setting is only effective for FAX/TAD mode.

[1.5 Cycle (Default)/ 2.0 Cycle]

Tone Sound Monitoring

Determines the period when tones from the line are monitored.

[No Monitoring/ Up To Phase B (Default)/ All TX Phases]

Stop/Clear Key

Pressing the Stop/Clear key can stop the current receiving operation. Received data is lost.

[No Functional (Default)/ Functional]

Off-Hook Detection

Sets the Off-Hook detection period.

[200 msec (Default)/ 800 msec]

Number for Remote Switch

[0~9 / 2 (Default/ 1digit/step]

Number of time to press

[1~3 / 2 (Default/ 1time/step]
Period: TEL to Fax[Limitless / 10 sec (Default/ 20 sec / 30 sec / 40 sec]
TX SettingsRedial Interval

Sets the redial interval when Tx fails.

[5 Min (Default)/ 6 Min]

Redialings

Sets the number of redials when Tx fails.

[2 times (Default)/ 3 Times/ 4 Times/ 5 Times]

Overseas Comm Mode SettingsOverseas Comm Mode

This sets the machine to ignore a DIS signal sent from the called station once in a sending operation.

[Off (Default)/ Ignore DIS Once]

 Minimum Time Length

If this setting is set to "On", the machine detects the CNG signal after the line is connected. If it is set to "Off", the machine detects the CNG signal as long as the line is connected.

[100 Ms/ 200 Ms/ 300 Ms/ 400 Ms (Default)]

Dial Pulse SettingDial Pulse Type

This sets the number of pulses that are generated during dialing.

  • N: Dialing '0' generates 10 pulses --- Dialing '9' generates 9 pulses. (Default)
  • N+1: Dialing '0' generates 1 pulses --- Dialing '9' generates 10 pulses.
  • 10-N: Dialing '0' generates 10 pulses --- Dialing '9' generates 1 pulse.
Tone Signal SettingsTone Signal Transmission T

Sets the tone signal transmission time length

[100 ms (Default)]

Minimum Pause In Tone Dial

Sets the minimum pause during tone dialing

[100 ms (Default)/ 150 ms/ 200 ms]

Attenuator of Pseudo Ring

Sets the attenuator for pseudo ringback tone to the line

[0 to 15 / 10 (Default)/ 1 dB/step]

DTMF Level

Sets the transmission level of DTMF tones.

[-12 dBu / -11 dBu/ -10 dBu (Default)/ -8 dBu/ -6 dBu]

DTMF Delta

Sets the level difference between high band frequency signals and low band frequency signals when sending DTMF tones.

[1 dBu/ 2 dBu (Default)/ 3 dBu]

1Dial Tone DetectionWait Time

The machine starts dialing after the specified interval without detection of a dial tone when dial tone detection is set to "No detection".

[3.5 Sec (Default)/ 7.0 Sec/ 10.5 Sec/ 14.0 Sec]

Timeout Length

This setting sets the time-out length for the 1st dial tone detection. The machine waits for a dial tone for the specified time and disconnects itself from the line when no dial tone is input.

[10 Sec (Default)/ 15 Sec/ 20 Sec/ 30 Sec]

BT (Busy Tone) DetectionBT Setting

DFU

[Off/ On(Default)]

BT Frequency

DFU

[300-550 Hz/ 300-650 Hz/ 325-525 Hz/ 340-550 Hz/ 350-500 Hz (Default)/ 350-550 Hz/ 375-475 Hz/ 380-520 Hz]

BT Level

DFU

[-35 dB/ -36 dB/ -37 dB/ -38 dB/ -39 dB (Default)]

BT Cadence

DFU

[0.10/ 0.15/ 0.20/ 0.25/ 0.30/ 0.35/ 0.40/ 0.45/ 0.50 (Default)/ 0.75]

Comm SettingsRTN Rate

The machine checks the actual data reconstruction errors and then transmits an RTN depending on the decoding error rate that is set by this setting (Number of lines containing an error per page / Total number of lines per page).

[10% (Default)/ 15%]

V34 Modem

DFU

[Permitted (Default)/ Prohibited]

V17 Modem

DFU

[Permitted (Default)/ Prohibited]

V34 SettingsEqualizer

DFU

These selectors set the equalizer's training level to be applied if training fails due to poor line connection.

[Automatic (Default)/ 4 Points/ 16 Points]

Redialing

Resend when a communication error occurs.

[Disabled (Default)/ Not Disabled]

First TX Speed

Sets the first transmission speed choice, before fallback.

[2400 Bps/ 4800 Bps/ 7200 Bps/ 9600 Bps/ 12000 Bps/ 14400 Bps/ 16800 Bps/ 19200 Bps/ 21600 Bps/ 24000 Bps/ 26400 Bps/ 28800 Bps/ 31200 Bps/ 33600 Bps (Default)]

Symbol Rate

This setting limits the transmission speed range in V.34 mode by masking the desired symbol rate(s).

[Not Used (Default)/ 3429 Sym/Sec/ 3200 Sym/Sec/ 3000 Sym/Sec/ 2800 Sym/Sec/ 2400 Sym/Sec]

All Document Transfer

Transfers all documents in fax memory to another fax machine. Emergency use only.

Input the forwarding fax number.

Max. 40 digits (includes #, *)

To start transferring all documents, press the “Start” key.

To cancel all documents from transferring and go back to the Fax Maintenance menu, press the “Clear/Stop” key.