No.

Type

Error Name/Error Condition/Major Cause/Solution

SC688

D

PRREQ signal not asserted

The print request signal (PRREQ) signal is not asserted within the prescribed time after paper reaches the registration stand-by position,
  • Main board error
  • Communication error
  1. Turn the power OFF and ON.
  2. Check the interface harness of the main board.