After replacing the main board, the following settings must be made correctly.

  1. Enter the "Maintenance Mode", and set the SPs below;
    • Destination
      Four-line LCD models: SP menu > [Engine Maintenance] > [Destination]
      Touch panel models: SP menu > [Engine Service Setting] > [Destination]

      DestinationMachine CodeSetting Value
      NAM0C3-17, M0C6-17, M0C4-17, M0C5-17, M0C7-171
      EU/AAM0C3-27, M0C6-27, M0C4-27, M0C5-27, M0C7-272
      CHNM0C3-21, M0C4-21, M0C5-214
      TWNM0C3-19, M0C5-195
    • Serial No.
      Four-line LCD models: SP menu > [Engine Maintenance] > [Serial No.]
      Touch panel models: SP menu > [Engine Service Setting] > [Serial No.]

      Ask your supervisor about how to enter the "Maintenance Mode".

  2. Do the registration adjustment (Registration Adjustment)
  3. For @Remote models, make sure that the manual call can be performed.

    If the serial number is not input correctly, @Remote service cannot be connected.