For MP 2555 SP/MP 3055 SP/MP 3555 SP
  • After the PM counter for the Fusing Belt (heating sleeve belt unit) reaches 260K pages or the PM counter distance reaches 139,378,000 mm, the machine stops automatically.
  • Replace the heating sleeve belt unit before the machine stops (stop warning: 240K pages, stop: 260K pages).
For MP4055 SP/MP 5055 SP/MP 6055 SP
  • After the PM counter for the Fusing Belt (heating sleeve belt unit) reaches 350K pages or the PM counter distance reaches 165,936,000 mm, the machine stops automatically.