SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC202-00 | D | Polygon Motor: ON Timeout Error |
After the polygon motor turned on, or within 10 sec. after the rpm’s changed, the motor did not enter READY status. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC203-00 | D | Polygon Motor: OFF Timeout Error |
The XSCRDY signal (polygon ready) never becomes inactive (H) within 3 sec. after the polygon motor went OFF. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC204-00 | D | Polygon Motor: XSCRDY Signal Error |
During polygon motor rotation, the XSCRDY signal was inactive (H) for longer than one rotation of the polygon. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC220-00 | D | Laser Synchronization Detection Error: Leading Edge |
The laser synchronizing detection signal for the start position of the LD was not output for 200msec. after LDB unit turned on with the polygon motor rotating normally. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC230-00 | D | FGATE ON Error |
The FGATE signal did not turn ON within the given time period after the writing process started. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC231-00 | D | FGATE OFF Error |
The FGATE signal did not turn OFF within the given time period after the writing process ended. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC240-00 | D | LD Error |
| ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC272-01 | D | LD Driver Communication Error |
If the value is not same when the machine reads and writes the same registration at the machine start-up. If the communication parity retries three consecutive times, the SC is generated. | ||
| ||
|
SC No. | Level | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC272-10 | D | LD Driver Communication Error: Others |
If the “Door Open” status does not change to “Door Close” after closing the door. | ||
| ||
|