Items

MP 2554/3054/3554/4054/5054/6054MP 2555/3055/3555/4055/5055/6055

Scanner type

-

Short focus scanner, for distortion correction:
After replacing the scanner carriage, the correction value specified on the supplied sheet in the SP code must be entered. For details, see Scanner Carriage.

Main scanning magnification adjustment

Not available

Magnification adjustment is available for the main scanning direction with SP4-871-003, -004.

Scanner shipping retainers-Provided
Oiling to guide railsLauna oilGrease
Scanner driveWith wire driveWith belt drive

Paper size detection
(main scanning direction, width)

Reading all lampsReading half lamps in the front side

Paper size detection

(sub scanning direction, length)

Put one reflecting sensor in a vertical direction.Put one reflecting sensor in a horizontal direction.
Option heaterAttach the heater at an angle in the center of the bottom plate.Attach the heater horizontally in the left rear of the bottom plate.