Items | MP 2554/3054/3554/4054/5054/6054 | MP 2555/3055/3555/4055/5055/6055 |
---|---|---|
Scanner type | - | Short focus scanner, for distortion correction: |
Main scanning magnification adjustment | Not available | Magnification adjustment is available for the main scanning direction with SP4-871-003, -004. |
Scanner shipping retainers | - | Provided |
Oiling to guide rails | Launa oil | Grease |
Scanner drive | With wire drive | With belt drive |
Paper size detection | Reading all lamps | Reading half lamps in the front side |
Paper size detection (sub scanning direction, length) | Put one reflecting sensor in a vertical direction. | Put one reflecting sensor in a horizontal direction. |
Option heater | Attach the heater at an angle in the center of the bottom plate. | Attach the heater horizontally in the left rear of the bottom plate. |