A: Leading Edge Registration
B: Side-to-side Registration
- Use A3/DLT paper to make a temporary test chart as shown above.
- Put the temporary test chart on the ARDF. Then make a copy from one of the feed stations.
Check the registration. Check the leading edge and side-to-side registration. Adjust the following SP modes if necessary.
Standard: 4.2 ± 2 mm for the leading edge registration, 2 ± 1 mm for the side-to-side registration. Use the following SP modes to adjust if necessary.
ARDF DF3090
SP No.
SP Name
Adjustment Range
SP6-006-001
Side-to-Side Regist: Front
±3.0 mm
SP6-006-002
Side-to-Side Regist: Rear
±3.0 mm
SP6-006-003
Leading Edge Registration: Front
±5.0 mm
SP6-006-004
Leading Edge Registration: Rear
±5.0 mm
SP6-006-005
Buckle: Duplex Front
±5.0 mm
SP6-006-006
Buckle: Duplex Rear
±5.0 mm
SP6-006-007
Rear Edge Erase Front
±10.0 mm
SP6-006-008
Rear Edge Erase Rear
±10.0 mm
SPDF DF3100
SP No.
SP Name
Adjustment Range
SP6-006-001
Side-to-Side Regist: Front
±3.0 mm
SP6-006-002
Side-to-Side Regist: Rear
±3.0 mm
SP6-006-010
L-Edge Regist (1-Pass): Front
±5.0 mm
SP6-006-011
L-Edge Regist (1-Pass): Rear
±5.0 mm
SP6-006-012
1st Buckle (1-Pass)
±3.0 mm
SP6-006-013
2nd Buckle (1-Pass)
-2 to +3 mm
SP6-006-014
T-Edge Erase (1-Pass): Front
±5.0 mm
SP6-006-015
T-Edge Erase (1-Pass): Rear
±5.0 mm